FLUID-SENSITIVE SEQUENCES MODIFY THE MODIC CLASSIFICATION IN MRI

ABSTRACT Objective: To evaluate whether the magnetic resonance imaging (MRI) acquisition with the Dixon fat suppression technique alters the detection of signal abnormalities in the subchondral bone of the vertebral endplates in the lumbar spine. Methods: retrospective study include patients who underwent lumbar spine MRI with acquisition of T1- and T2-weighted fast spin echo sequences (routine protocol) and the multipoint Dixon sequence with T2 weighting and fat suppression. Two radiologists qualitatively classified Modic-type changes (absent, Modic I, Modic II, and Modic III) independently and blindly. When the subchondral signal abnormality was identified, each radiologist measured the maximum depth in relation to the vertebral plateau. The radiologists’ assessments were used to analyze interobserver agreement and one of the radiologists carried out a second analysis of the exams, enabling intra-observer assessment. Results: The results showed a significant increase in the detection of the edema pattern (Modic I) in qualitative and quantitative analyzes when using the Dixon technique, in comparison to the routine sequences, with an increase in the prevalence and extent of involvement by the bone edema pattern. There was no significant difference in the detection of the adipose replacement pattern (Modic II) between the two techniques. There was moderate to substantial intra-observer correlation for the traditional protocol and substantial to high agreement for the analysis of the Dixon technique images. Conclusions: The Dixon technique showed superiority in the detection of Modic I in relation to the traditional protocol, and allowed the detection, on average, of greater depth of involvement of subchondral bone changes. There was good intra-observer and inter-observer reproducibility in identifying Modic abnormalities. Evidence level III, comparative retrospective study.

Authors

Institutions

Publication Details

Journal
Coluna/Columna
Published
2025-01-01
DOI
https://doi.org/10.1590/s1808-185120252401292286
Primary Topic
Fuzzy Logic and Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FLUID-SENSITIVE SEQUENCES MODIFY THE MODIC CLASSIFICATION IN MRI

Marcelo Novelino Simão, Marcello Henrique Nogueira‐Barbosa, Eduardo do Nascimento
Coluna/Columna
Fuzzy Logic and Control Systems
article

FLUID-SENSITIVE SEQUENCES MODIFY THE MODIC CLASSIFICATION IN MRI

Marcelo Novelino Simão, Marcello Henrique Nogueira‐Barbosa, Eduardo do Nascimento
article en

Abstract

ABSTRACT Objective: To evaluate whether the magnetic resonance imaging (MRI) acquisition with the Dixon fat suppression technique alters the detection of signal abnormalities in the subchondral bone of the vertebral endplates in the lumbar spine. Methods: retrospective study include patients who underwent lumbar spine MRI with acquisition of T1- and T2-weighted fast spin echo sequences (routine protocol) and the multipoint Dixon sequence with T2 weighting and fat suppression. Two radiologists qualitatively classified Modic-type changes (absent, Modic I, Modic II, and Modic III) independently and blindly. When the subchondral signal abnormality was identified, each radiologist measured the maximum depth in relation to the vertebral plateau. The radiologists’ assessments were used to analyze interobserver agreement and one of the radiologists carried out a second analysis of the exams, enabling intra-observer assessment. Results: The results showed a significant increase in the detection of the edema pattern (Modic I) in qualitative and quantitative analyzes when using the Dixon technique, in comparison to the routine sequences, with an increase in the prevalence and extent of involvement by the bone edema pattern. There was no significant difference in the detection of the adipose replacement pattern (Modic II) between the two techniques. There was moderate to substantial intra-observer correlation for the traditional protocol and substantial to high agreement for the analysis of the Dixon technique images. Conclusions: The Dixon technique showed superiority in the detection of Modic I in relation to the traditional protocol, and allowed the detection, on average, of greater depth of involvement of subchondral bone changes. There was good intra-observer and inter-observer reproducibility in identifying Modic abnormalities. Evidence level III, comparative retrospective study.

Coluna/ColumnaVol. 24(1)
Universidade de São Paulo (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Openalex Percentile: Top 95%
Fuzzy Logic and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

FLUID-SENSITIVE SEQUENCES MODIFY THE MODIC CLASSIFICATION IN MRI — Marcelo Novelino Simão, Marcello Henrique Nogueira‐Barbosa, et al. · Coluna/Columna (2025) | TGRS Research Map | TGRS