Spatial and temporal validation of urban microclimate simulations

Abstract Understanding Urban Heat Islands is crucial for effective urban adaptation policies. Despite advances in simulation models, validation gaps remain, particularly in capturing microclimatic variations at the pedestrian scale. This study integrates dynamic monitoring with a low-cost portable device and validation using fixed and dynamic data to enhance CFD (Computational fluid dynamics) model accuracy. The objective is to assess an urban microclimate CFD model through temporal and spatial validation. Monitoring was conducted in Curitiba using a fixed reference station and a Low-Cost Portable Environmental Monitoring System (PLEMS) (1); a CFD model was developed and simulated in ENVI-met (2); and statistical validation metrics were analyzed (3). While temporal validation showed high agreement with low error magnitudes, spatial validation revealed low accuracy in predicting thermal comfort in urban canyons. Differences between intra-urban transect and simulated data highlight the need for model calibration.

Authors

Institutions

Publication Details

Journal
Ambiente Construído
Published
2025-01-01
DOI
https://doi.org/10.1590/s1678-86212025000100895
Citations
1
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatial and temporal validation of urban microclimate simulations

Solange Maria Leder, Bianca Milani de Quadros, Anna Laura Pisello, Eduardo Leite Krüger et al.
1 citations
Ambiente Construído
Urban Heat Island Mitigation
0.80
article

Spatial and temporal validation of urban microclimate simulations

Solange Maria Leder, Bianca Milani de Quadros, Anna Laura Pisello, Eduardo Leite Krüger, Ilaria Pigliautile, Walter Ihlenfeld, Martin Órdenes Mizgier
article en
1 citations

Abstract

Abstract Understanding Urban Heat Islands is crucial for effective urban adaptation policies. Despite advances in simulation models, validation gaps remain, particularly in capturing microclimatic variations at the pedestrian scale. This study integrates dynamic monitoring with a low-cost portable device and validation using fixed and dynamic data to enhance CFD (Computational fluid dynamics) model accuracy. The objective is to assess an urban microclimate CFD model through temporal and spatial validation. Monitoring was conducted in Curitiba using a fixed reference station and a Low-Cost Portable Environmental Monitoring System (PLEMS) (1); a CFD model was developed and simulated in ENVI-met (2); and statistical validation metrics were analyzed (3). While temporal validation showed high agreement with low error magnitudes, spatial validation revealed low accuracy in predicting thermal comfort in urban canyons. Differences between intra-urban transect and simulated data highlight the need for model calibration.

Ambiente ConstruídoVol. 25
Universidade Tecnológica Federal do Paraná (BR), Università degli Studi eCampus (IT), Universidade Federal da Paraíba (BR), University of Perugia (IT), Universidade Federal de Santa Catarina (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, HORIZON EUROPE Framework Programme, European Social Fund
Openalex Percentile: Top 30%
Urban Heat Island Mitigation
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Spatial and temporal validation of urban microclimate simulations — Solange Maria Leder, Bianca Milani de Quadros, et al. · Ambiente Construído (2025) | TGRS Research Map | TGRS