Case of intestinal obstruction due to accidental ingestion of a silicone rubber dental impression

Accidental ingestion is common and can even necessitate surgery. An 89-year-old man with dementia presented with abdominal distension and pain. A CT scan revealed a high-intensity object in the terminal ileum with distension of the proximal small intestine. Colonoscopy showed ileus caused by a retained foreign body (FB), which was removed via laparotomy the following day. Chemical analysis identified the material of the FB as platinum silicone rubber. Based on its material and irregular shape, the FB was determined to be a dental impression. The patient had dentures made one year prior, and cognitive decline may have contributed to the incident. Platinum silicone, which is odorless and does not deform with body heat or digestive juices, maybe a common cause of accidental ingestion.

Authors

Institutions

Publication Details

Journal
Journal of Surgical Case Reports
Published
2025-04-29
DOI
https://doi.org/10.1093/jscr/rjaf195
Primary Topic
Foreign Body Medical Cases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case of intestinal obstruction due to accidental ingestion of a silicone rubber dental impression

Yuichi Nagakawa, Kazuhiko Kasuya, Shingo Tachibana, Yuki Takano et al.
Journal of Surgical Case Reports
Foreign Body Medical Cases
article

Case of intestinal obstruction due to accidental ingestion of a silicone rubber dental impression

Yuichi Nagakawa, Kazuhiko Kasuya, Shingo Tachibana, Yuki Takano, Keigo Fugami
article en

Abstract

Accidental ingestion is common and can even necessitate surgery. An 89-year-old man with dementia presented with abdominal distension and pain. A CT scan revealed a high-intensity object in the terminal ileum with distension of the proximal small intestine. Colonoscopy showed ileus caused by a retained foreign body (FB), which was removed via laparotomy the following day. Chemical analysis identified the material of the FB as platinum silicone rubber. Based on its material and irregular shape, the FB was determined to be a dental impression. The patient had dentures made one year prior, and cognitive decline may have contributed to the incident. Platinum silicone, which is odorless and does not deform with body heat or digestive juices, maybe a common cause of accidental ingestion.

Journal of Surgical Case ReportsVol. 2025(5)
Tokyo Medical University (JP)
Openalex Percentile: Top 84%
Foreign Body Medical Cases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.