INNOVATIVE FETAL MONITORING SYSTEM USING BIOIMPEDANCE TECHNIQUE OF DESIGN, VALIDATION, AND BENEFITS

This research introduces a unique fetal monitoring system grounded in the bioimpedance technique, also recognized as Electrical Impedance Tomography (EIT). The mechanism comprises a phantom, experimental setup, and information acquisition methods, designed to evaluate its capacity via phantom (mother)-based complete evaluations. To validate its effectiveness, a sequence of experiments are performed with the use of diverse phantoms geared up with 8, or 4 electrodes. By making use of EIT current patterns and measuring the ensuing voltage points, the device’s abilities have been assessed. The proposed EIT-based fetal monitoring system achieved accurate impedance measurements with voltage outputs ranging from 0.3 mV to 4.38 mV across various phantoms. EIT gives distinct advantages over traditional imaging modalities, allowing noninvasive monitoring and recording of dispensed electric-powered fields within a closed object. This revolutionary approach is characterized by its person-pleasant interface, affordability, and suitability for mass healthcare applications, making it available to underserved communities and primary healthcare workers.

Authors

Institutions

Publication Details

Journal
Biomedical Engineering Applications Basis and Communications
Published
2025-05-15
DOI
https://doi.org/10.4015/s1016237225500188
Citations
1
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INNOVATIVE FETAL MONITORING SYSTEM USING BIOIMPEDANCE TECHNIQUE OF DESIGN, VALIDATION, AND BENEFITS

Arjun Puri, Ashish Kumar Singh, Gaurav Sharma, Ramesh Kumar et al.
1 citations
Biomedical Engineering Applications Basis and Communications
Electrical and Bioimpedance Tomography
0.73
article

INNOVATIVE FETAL MONITORING SYSTEM USING BIOIMPEDANCE TECHNIQUE OF DESIGN, VALIDATION, AND BENEFITS

Arjun Puri, Ashish Kumar Singh, Gaurav Sharma, Ramesh Kumar, Manish Kumar Singla
article en
1 citations

Abstract

This research introduces a unique fetal monitoring system grounded in the bioimpedance technique, also recognized as Electrical Impedance Tomography (EIT). The mechanism comprises a phantom, experimental setup, and information acquisition methods, designed to evaluate its capacity via phantom (mother)-based complete evaluations. To validate its effectiveness, a sequence of experiments are performed with the use of diverse phantoms geared up with 8, or 4 electrodes. By making use of EIT current patterns and measuring the ensuing voltage points, the device’s abilities have been assessed. The proposed EIT-based fetal monitoring system achieved accurate impedance measurements with voltage outputs ranging from 0.3 mV to 4.38 mV across various phantoms. EIT gives distinct advantages over traditional imaging modalities, allowing noninvasive monitoring and recording of dispensed electric-powered fields within a closed object. This revolutionary approach is characterized by its person-pleasant interface, affordability, and suitability for mass healthcare applications, making it available to underserved communities and primary healthcare workers.

Biomedical Engineering Applications Basis and CommunicationsVol. 38(01)
Applied Science Private University (JO), Graphic Era University (IN), Chitkara University (IN), Saveetha University (IN)
Science and Engineering Research Board
Openalex Percentile: Top 28%
Electrical and Bioimpedance Tomography
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

INNOVATIVE FETAL MONITORING SYSTEM USING BIOIMPEDANCE TECHNIQUE OF DESIGN, VALIDATION, AND BENEFITS — Arjun Puri, Ashish Kumar Singh, et al. · Biomedical Engineering Applications Basis and Communications (2025) | TGRS Research Map | TGRS