Evaluation of internal fixation stability of distal humerus C-type fractures based on musculoskeletal dynamics: finite element analysis under dynamic loading

In this study, we quantified the mechanical effect of muscle contraction force on the stability of internal fixation of distal humerus C-type fracture and revealed the biomechanical law in the postoperative period; we established a simulation model of dynamic and static loading and proposed a 'safe activity window' for postoperative exercise, which confirms the high stiffness of the parallel steel plate and the control of the angle of early active activity (≤ 80° of flexion). Flexion of more than 30° in the case of vertical plates leads to shear micromotion overruns (> 0.48 mm).

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Surgery and Research
Published
2025-05-17
DOI
https://doi.org/10.1186/s13018-025-05876-z
Citations
1
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of internal fixation stability of distal humerus C-type fractures based on musculoskeletal dynamics: finite element analysis under dynamic loading

Weilu Gao, Peifu Tang, Zhengfeng Jia, Chi Yang et al.
1 citations
Journal of Orthopaedic Surgery and Research
Orthopedic Surgery and Rehabilitation
2.01
article

Evaluation of internal fixation stability of distal humerus C-type fractures based on musculoskeletal dynamics: finite element analysis under dynamic loading

Weilu Gao, Peifu Tang, Zhengfeng Jia, Chi Yang, Jiantao Li, Cheng Xu
article en
1 citations

Abstract

In this study, we quantified the mechanical effect of muscle contraction force on the stability of internal fixation of distal humerus C-type fracture and revealed the biomechanical law in the postoperative period; we established a simulation model of dynamic and static loading and proposed a 'safe activity window' for postoperative exercise, which confirms the high stiffness of the parallel steel plate and the control of the angle of early active activity (≤ 80° of flexion). Flexion of more than 30° in the case of vertical plates leads to shear micromotion overruns (> 0.48 mm).

Journal of Orthopaedic Surgery and ResearchVol. 20(1)
Chinese PLA General Hospital (CN)
Openalex Percentile: Top 16%
Orthopedic Surgery and Rehabilitation
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.