Improving necrosis estimation in MR-guided prostate focused ultrasound ablations with a probabilistic thermal dose model

False positive necrosis classification close to ablation zones in magnetic resonance (MR)-guided transurethral ultrasound ablation of the prostate poses an issue for real-time assessment of the treatment. Typically, apriori knowledge about transducers is utilized to filter temperature maps, thereby reducing false positives. Our innovation, however, lies in the ability of our probabilistic CEM<sub>43</sub> thermal dose model (pCEM<sub>43</sub>) to decrease false positives without the need for prior knowledge beyond the noise statistics estimated from baseline images. The original pCEM<sub>43</sub> was modified improving statistical thermal dose estimation and applied to transurethral ultrasound ablations. The modified model was evaluated on 22 ablation data sets to determine its accuracy and computation time. MR thermometry was acquired by the TULSA Pro system with an EPI sequence using the proton resonance frequency shift (PRFS). Accuracy was determined with Sørensen-Dice coefficients (DSC), relative false positive rates (rFPR), sensitivities. Additionally, over- and underestimation of ablation volumes was investigated with mean contour overestimation (MCO) and mean contour underestimation (MCU) metrics. Results of pCEM<sub>43</sub> were compared to an unfiltered CEM<sub>43</sub> (CEM<sub>43</sub>) and a spatiotemporally filtered CEM<sub>43</sub> model (STF-CEM<sub>43</sub>). Computation times were measured for each data set and compared between models. Median DSCs were 38.9% (32.4%-49.3%), 64.2% (53.7%-73.6%), and 70.7% (66.6%-76.3%) (p≤0.001) for the CEM<sub>43</sub>, the STF-CEM<sub>43</sub>, and the pCEM<sub>43</sub> model, respectively. Mean rFPRs were 2.18 ±1.03, 0.61 ±0.39, and 0.32 ±0.28 (p≤0.001), and median sensitivities were 75.6% (71.7%-83.1%), 72.0% (66.0%-76.2%), and 70.6% (65.1%-74.5%) (p≤0.001), respectively. Median MCOs were 21.3 (13.7 - 43.0), 1.1 (0.6 - 2.1), and 0.5 (0.3 - 0.8) (p≤0.001) for the CEM<sub>43</sub>, the STF-CEM<sub>43</sub>, and the pCEM<sub>43</sub> model, respectively. Mean MCUs were 0.6 ±0.4, 0.5 ±0.2, and 0.5 ±0.2 (p=0.025). The modified pCEM<sub>43</sub> improves monitoring accuracy and reduces overestimation of ablation volumes without the need for hardware-specific apriori knowledge in real-time. This could increase success rates of treatments and reduce the risk of underablation and subsequent recurrence of tumors. To determine the generalizability of the proposed model, future work will be concerned with performing evaluations for different thermoablation techniques in different types of tissue.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2025-05-16
DOI
https://doi.org/10.1016/j.compbiomed.2025.110225
Citations
1
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving necrosis estimation in MR-guided prostate focused ultrasound ablations with a probabilistic thermal dose model

Inga Peters, Daniel Düx, Julian Glandorf, Bennet Hensen et al.
1 citations
Computers in Biology and Medicine
Ultrasound and Hyperthermia Applications
0.67
article

Improving necrosis estimation in MR-guided prostate focused ultrasound ablations with a probabilistic thermal dose model

Inga Peters, Daniel Düx, Julian Glandorf, Bennet Hensen, Dominik Horstmann, Simon Schröer, Susanne Hellms, Frank K. Wacker, Othmar Belker, Marcel Gutberlet, Moritz Gutt
article en
1 citations

Abstract

False positive necrosis classification close to ablation zones in magnetic resonance (MR)-guided transurethral ultrasound ablation of the prostate poses an issue for real-time assessment of the treatment. Typically, apriori knowledge about transducers is utilized to filter temperature maps, thereby reducing false positives. Our innovation, however, lies in the ability of our probabilistic CEM<sub>43</sub> thermal dose model (pCEM<sub>43</sub>) to decrease false positives without the need for prior knowledge beyond the noise statistics estimated from baseline images. The original pCEM<sub>43</sub> was modified improving statistical thermal dose estimation and applied to transurethral ultrasound ablations. The modified model was evaluated on 22 ablation data sets to determine its accuracy and computation time. MR thermometry was acquired by the TULSA Pro system with an EPI sequence using the proton resonance frequency shift (PRFS). Accuracy was determined with Sørensen-Dice coefficients (DSC), relative false positive rates (rFPR), sensitivities. Additionally, over- and underestimation of ablation volumes was investigated with mean contour overestimation (MCO) and mean contour underestimation (MCU) metrics. Results of pCEM<sub>43</sub> were compared to an unfiltered CEM<sub>43</sub> (CEM<sub>43</sub>) and a spatiotemporally filtered CEM<sub>43</sub> model (STF-CEM<sub>43</sub>). Computation times were measured for each data set and compared between models. Median DSCs were 38.9% (32.4%-49.3%), 64.2% (53.7%-73.6%), and 70.7% (66.6%-76.3%) (p≤0.001) for the CEM<sub>43</sub>, the STF-CEM<sub>43</sub>, and the pCEM<sub>43</sub> model, respectively. Mean rFPRs were 2.18 ±1.03, 0.61 ±0.39, and 0.32 ±0.28 (p≤0.001), and median sensitivities were 75.6% (71.7%-83.1%), 72.0% (66.0%-76.2%), and 70.6% (65.1%-74.5%) (p≤0.001), respectively. Median MCOs were 21.3 (13.7 - 43.0), 1.1 (0.6 - 2.1), and 0.5 (0.3 - 0.8) (p≤0.001) for the CEM<sub>43</sub>, the STF-CEM<sub>43</sub>, and the pCEM<sub>43</sub> model, respectively. Mean MCUs were 0.6 ±0.4, 0.5 ±0.2, and 0.5 ±0.2 (p=0.025). The modified pCEM<sub>43</sub> improves monitoring accuracy and reduces overestimation of ablation volumes without the need for hardware-specific apriori knowledge in real-time. This could increase success rates of treatments and reduce the risk of underablation and subsequent recurrence of tumors. To determine the generalizability of the proposed model, future work will be concerned with performing evaluations for different thermoablation techniques in different types of tissue.

Computers in Biology and MedicineVol. 192(Pt B)
Medizinische Hochschule Hannover (DE), Krankenhaus Nordwest (DE)
Zero hunger
Openalex Percentile: Top 32%
Ultrasound and Hyperthermia Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.