Assessing Circuit Breaker Gas Pressure Using Temperature Analysis

Monitoring gas pressure in circuit breakers is essential to ensure dielectric strength and effective arc-quenching performance. This study presents a smart thermal monitoring approach for assessing circuit breaker gas pressure changes inside the arc chamber, enabling the detection of indirect and real-time gas leakage. Simulations were conducted to analyze the circuit breaker's thermal response under various gas pressure conditions. Results indicate that reduced SF6 pressure can lead to contact temperatures exceeding the IEC 62271–100 limit of 110°C, due to diminished heat transfer efficiency. This approach emphasizes the importance of simultaneous gas pressure and temperature monitoring as a predictive maintenance tool. It enhances circuit breakers' reliability and operational safety by allowing early detection of gas leaks and preventing equipment damage.

Authors

Institutions

Publication Details

Published
2024-12-31
DOI
https://doi.org/10.1109/sgc64640.2024.10983718
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Circuit Breaker Gas Pressure Using Temperature Analysis

Ali A. Razi‐Kazemi, Mohsen Taghizadeh Kejani, Seyed Hamid Khalkhali, Zahra Zamani
Vacuum and Plasma Arcs
article

Assessing Circuit Breaker Gas Pressure Using Temperature Analysis

Ali A. Razi‐Kazemi, Mohsen Taghizadeh Kejani, Seyed Hamid Khalkhali, Zahra Zamani
article en

Abstract

Monitoring gas pressure in circuit breakers is essential to ensure dielectric strength and effective arc-quenching performance. This study presents a smart thermal monitoring approach for assessing circuit breaker gas pressure changes inside the arc chamber, enabling the detection of indirect and real-time gas leakage. Simulations were conducted to analyze the circuit breaker's thermal response under various gas pressure conditions. Results indicate that reduced SF6 pressure can lead to contact temperatures exceeding the IEC 62271–100 limit of 110°C, due to diminished heat transfer efficiency. This approach emphasizes the importance of simultaneous gas pressure and temperature monitoring as a predictive maintenance tool. It enhances circuit breakers' reliability and operational safety by allowing early detection of gas leaks and preventing equipment damage.

K. N. Toosi University of Technology (IR)
Affordable and clean energy
Openalex Percentile: Top 76%
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing Circuit Breaker Gas Pressure Using Temperature Analysis — Ali A. Razi‐Kazemi, Mohsen Taghizadeh Kejani, et al. · (2024) | TGRS Research Map | TGRS