Dual-Polarized Water-Substrate-Based MIMO Implantable Antenna for IoMT-Enabled Biotelemetric Devices

This paper introduces a water-substrate-based implantable antenna (WSIA) that can be easily adapted to 2-and 4-elements multiple-input multiple-output (MIMO) configurations for high-data-rate Internet of Medical Things (IoMT) devices. The proposed antenna operates in the 2.45-GHz industrial, scientific, and medical band for biotelemetry and in the 1.47-GHz midfield band for the seamless wireless powering of IoMT devices. Compared with previously reported implantable antennas, the proposed MIMO antenna element is ultra-miniaturized, achieved through high water permittivity and a circular ring-shaped radiator. Additionally, the antenna elements are strategically positioned for 2-and 4-ports MIMO configurations to achieve polarization diversity (PD), improving isolation and overall system efficiency. The antennas were optimized within a realistic capsule containing electronic components, sensors, and batteries and were subsequently fabricated and tested. In addition to satisfactory performance in terms of scattering parameters, isolation, gain, and polarization diversity, the proposed MIMO antenna systems exhibited significantly lower specific absorption rates (SARs) owing to water substrate, thereby offering improved user safety. Evaluation of the MIMO performance, focusing on the envelope correlation coefficient and diversity gain, yielded results within acceptable limits, even in diverse body environments. Moreover, a link-budget analysis revealed that the antennas can establish a reliable communication link at distances of 20 and 15 m at 1.47 and 2.45 GHz, respectively with high-data-rate of 100 Mb/s. Owing to the similarity between the electrical properties of water and human tissue, the proposed WSIAs efficiently transform radiated energy and, being 3D printable, offer significantly lower fabrication costs than conventional substrate-based designs. With advantages such as compact size, multi-band operations, PD, low SAR, and reduced fabrication costs, these antennas offer substantial benefits for IoMT implants, particularly for wireless capsule endoscopy.

Authors

Institutions

Publication Details

Journal
IEEE Internet of Things Journal
Published
2025-05-16
DOI
https://doi.org/10.1109/jiot.2025.3570779
Citations
6
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
4.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-Polarized Water-Substrate-Based MIMO Implantable Antenna for IoMT-Enabled Biotelemetric Devices

Naeem Abbas, Hyoungsuk Yoo, Zain U Abdin, Izaz Ali Shah
6 citations
IEEE Internet of Things Journal
Wireless Body Area Networks
4.04
article

Dual-Polarized Water-Substrate-Based MIMO Implantable Antenna for IoMT-Enabled Biotelemetric Devices

Naeem Abbas, Hyoungsuk Yoo, Zain U Abdin, Izaz Ali Shah
article en
6 citations

Abstract

This paper introduces a water-substrate-based implantable antenna (WSIA) that can be easily adapted to 2-and 4-elements multiple-input multiple-output (MIMO) configurations for high-data-rate Internet of Medical Things (IoMT) devices. The proposed antenna operates in the 2.45-GHz industrial, scientific, and medical band for biotelemetry and in the 1.47-GHz midfield band for the seamless wireless powering of IoMT devices. Compared with previously reported implantable antennas, the proposed MIMO antenna element is ultra-miniaturized, achieved through high water permittivity and a circular ring-shaped radiator. Additionally, the antenna elements are strategically positioned for 2-and 4-ports MIMO configurations to achieve polarization diversity (PD), improving isolation and overall system efficiency. The antennas were optimized within a realistic capsule containing electronic components, sensors, and batteries and were subsequently fabricated and tested. In addition to satisfactory performance in terms of scattering parameters, isolation, gain, and polarization diversity, the proposed MIMO antenna systems exhibited significantly lower specific absorption rates (SARs) owing to water substrate, thereby offering improved user safety. Evaluation of the MIMO performance, focusing on the envelope correlation coefficient and diversity gain, yielded results within acceptable limits, even in diverse body environments. Moreover, a link-budget analysis revealed that the antennas can establish a reliable communication link at distances of 20 and 15 m at 1.47 and 2.45 GHz, respectively with high-data-rate of 100 Mb/s. Owing to the similarity between the electrical properties of water and human tissue, the proposed WSIAs efficiently transform radiated energy and, being 3D printable, offer significantly lower fabrication costs than conventional substrate-based designs. With advantages such as compact size, multi-band operations, PD, low SAR, and reduced fabrication costs, these antennas offer substantial benefits for IoMT implants, particularly for wireless capsule endoscopy.

IEEE Internet of Things JournalVol. 12(15)
Hanyang University (KR)
Openalex Percentile: Top 6%
Wireless Body Area Networks
4.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.