Musculoskeletal Model-Based Adaptive Variable Impedance Control With Flexible Prescribed Performance for Rehabilitation Robots

In rehabilitation robotics, both compliance and high-precision motion are critical to effective rehabilitation training. However, there is an inherent conflict between system compliance and control accuracy, which presents significant challenges in achieving optimal performance. To address this issue, this article proposes a surface electromyogram (sEMG)-driven musculoskeletal model-based adaptive variable impedance controller with flexible prescribed performance, ensuring a balance between compliance and precision motion in the human–robot interaction. We begin by formulating a constrained human–robot system and subsequently transform it into an unconstrained system using prescribed performance techniques. A novel impedance model is introduced to ensure system stability while maintaining prescribed performance. Furthermore, the controller integrates the Joint Strength Index, derived from an sEMG-driven musculoskeletal model, and incorporates a flexible prescribed performance function combined with adaptive stiffness and damping. The method supports both robot-dominant and human-dominant modes, and the seamless transition between them. Our findings show that lower human involvement increases system stiffness and narrows motion constraints, enabling high-precision motion. In contrast, greater human participation improves system compliance and broadens motion constraints, allowing for more freedom of movement. Finally, experiments were conducted on an upper-limb rehabilitation robot to validate the proposed method.

Authors

Institutions

Publication Details

Journal
IEEE/ASME Transactions on Mechatronics
Published
2025-05-16
DOI
https://doi.org/10.1109/tmech.2025.3562670
Citations
4
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
4.10

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Musculoskeletal Model-Based Adaptive Variable Impedance Control With Flexible Prescribed Performance for Rehabilitation Robots

Shuhao Ma, Mengshi Zhang, Zhiqiang Zhang, Yu Cao et al.
4 citations
IEEE/ASME Transactions on Mechatronics
Stroke Rehabilitation and Recovery
4.10
article

Musculoskeletal Model-Based Adaptive Variable Impedance Control With Flexible Prescribed Performance for Rehabilitation Robots

Shuhao Ma, Mengshi Zhang, Zhiqiang Zhang, Yu Cao, Jian Huang, Zijian Li, Jindong Liu
article en
4 citations

Abstract

In rehabilitation robotics, both compliance and high-precision motion are critical to effective rehabilitation training. However, there is an inherent conflict between system compliance and control accuracy, which presents significant challenges in achieving optimal performance. To address this issue, this article proposes a surface electromyogram (sEMG)-driven musculoskeletal model-based adaptive variable impedance controller with flexible prescribed performance, ensuring a balance between compliance and precision motion in the human–robot interaction. We begin by formulating a constrained human–robot system and subsequently transform it into an unconstrained system using prescribed performance techniques. A novel impedance model is introduced to ensure system stability while maintaining prescribed performance. Furthermore, the controller integrates the Joint Strength Index, derived from an sEMG-driven musculoskeletal model, and incorporates a flexible prescribed performance function combined with adaptive stiffness and damping. The method supports both robot-dominant and human-dominant modes, and the seamless transition between them. Our findings show that lower human involvement increases system stiffness and narrows motion constraints, enabling high-precision motion. In contrast, greater human participation improves system compliance and broadens motion constraints, allowing for more freedom of movement. Finally, experiments were conducted on an upper-limb rehabilitation robot to validate the proposed method.

IEEE/ASME Transactions on MechatronicsVol. 30(4)
University of Leeds (GB), Fosun Pharma (China) (CN), Huazhong University of Science and Technology (CN)
Royal Society, National Natural Science Foundation of China
Openalex Percentile: Top 6%
Stroke Rehabilitation and Recovery
4.10
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.