Assessing Ultrasound Safety: A Method for Correlating Stimulus Parameters With MI and TI

Diagnostic ultrasound safety indices, such as the mechanical index (MI) and the thermal index (TI), serve as approved risk estimators of bioeffects that can result from an ultrasound stimulus. However, especially in ultrasound-based indirect therapeutic applications, only the MI is reported while the TI is overlooked, possibly due to its complex calculation. To simplify the calculation, we present an analytical-numerical method for computing the TI, restricted to the -6-dB region of the ultrasound beam, based on equations provided by the International Electrotechnical Commission (IEC) standards. Central to this calculation is the assumption of a linearly propagating ultrasound wave with minimal nonlinear distortion. This assumption was verified by COMSOL simulations and hydrophone measurements in a two-layer setup consisting of water and a tissue-mimicking phantom (TMP) for a single-element, spherically focusing transducer with a central opening driven at a frequency of 950 kHz. For this configuration, the peak-rarefactional pressure (PRP) was evaluated up to 1.5 MPa. To facilitate the immediate assessment of ultrasound safety, MI and TI were mapped into characteristic diagrams, correlating them with pulse durations (PDs) between 0.1 and 3.5 ms at a pulse repetition period (PRPP) of 0.1 s and PDs between 0.01 and 0.35 ms at a PRPP of 0.01 s. These diagrams serve as a practical tool for determining whether an ultrasound stimulus adheres to diagnostic safety limits for MI and TI.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2025-05-16
DOI
https://doi.org/10.1109/tuffc.2025.3570878
Citations
1
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Ultrasound Safety: A Method for Correlating Stimulus Parameters With MI and TI

Benedikt George, Stefan J. Rupitsch
1 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Ultrasound and Hyperthermia Applications
0.67
article

Assessing Ultrasound Safety: A Method for Correlating Stimulus Parameters With MI and TI

Benedikt George, Stefan J. Rupitsch
article en
1 citations

Abstract

Diagnostic ultrasound safety indices, such as the mechanical index (MI) and the thermal index (TI), serve as approved risk estimators of bioeffects that can result from an ultrasound stimulus. However, especially in ultrasound-based indirect therapeutic applications, only the MI is reported while the TI is overlooked, possibly due to its complex calculation. To simplify the calculation, we present an analytical-numerical method for computing the TI, restricted to the -6-dB region of the ultrasound beam, based on equations provided by the International Electrotechnical Commission (IEC) standards. Central to this calculation is the assumption of a linearly propagating ultrasound wave with minimal nonlinear distortion. This assumption was verified by COMSOL simulations and hydrophone measurements in a two-layer setup consisting of water and a tissue-mimicking phantom (TMP) for a single-element, spherically focusing transducer with a central opening driven at a frequency of 950 kHz. For this configuration, the peak-rarefactional pressure (PRP) was evaluated up to 1.5 MPa. To facilitate the immediate assessment of ultrasound safety, MI and TI were mapped into characteristic diagrams, correlating them with pulse durations (PDs) between 0.1 and 3.5 ms at a pulse repetition period (PRPP) of 0.1 s and PDs between 0.01 and 0.35 ms at a PRPP of 0.01 s. These diagrams serve as a practical tool for determining whether an ultrasound stimulus adheres to diagnostic safety limits for MI and TI.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 72(7)
University of Freiburg (DE)
Deutsche Forschungsgemeinschaft
Zero hunger
Openalex Percentile: Top 32%
Ultrasound and Hyperthermia Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing Ultrasound Safety: A Method for Correlating Stimulus Parameters With MI and TI — Benedikt George, Stefan J. Rupitsch · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control (2025) | TGRS Research Map | TGRS