Conventional internal bone fixation methods use titanium or stainless-steel implants which require a second or multiple surgeries for removal, increasing the risk of infection that can be reduced by using bioresorbable implants. This study investigates the mechanical properties of LAE442 Mg Alloy for internal femoral fracture fixation using the Finite Element Analysis (FEA) technique. Four femoral models—Normal femur, Intertrochanteric, Subtrochanteric, and Shaft-fractured—were analyzed under a normal gait scenario. The maximum von Mises and shear stresses for the normal femur were 17% and 19.8% while for intertrochanteric, subtrochanteric, and shaft fractures were 38.9% and 43.5%, 47.2% and 51.6% and 35.6% and 38.7% respectively, compared to the yield strengths of LAE442 Mg alloy (193 MPa compressive, 90.8 MPa shear). The total deformations were also within a normal range of up to 2 mm, indicating that the alloy is fairly suitable for femoral load-bearing during a normal gait cycle.

Authors

Institutions

Publication Details

Published
2024-12-30
DOI
https://doi.org/10.1109/inmic64792.2024.11004411
Citations
1
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite Element Analysis of Bioresorbable LAE442 Magnesium Alloy Intramedullary Nail for Internal Femoral Fracture Fixation

Hafiz M. Sohail, Syeda Shifa Mannan Gilani, Zainab Ali, Muhammad Taha Bin Athar
1 citations
Hip and Femur Fractures
0.57
article

Finite Element Analysis of Bioresorbable LAE442 Magnesium Alloy Intramedullary Nail for Internal Femoral Fracture Fixation

Hafiz M. Sohail, Syeda Shifa Mannan Gilani, Zainab Ali, Muhammad Taha Bin Athar
article en
1 citations

Abstract

Conventional internal bone fixation methods use titanium or stainless-steel implants which require a second or multiple surgeries for removal, increasing the risk of infection that can be reduced by using bioresorbable implants. This study investigates the mechanical properties of LAE442 Mg Alloy for internal femoral fracture fixation using the Finite Element Analysis (FEA) technique. Four femoral models—Normal femur, Intertrochanteric, Subtrochanteric, and Shaft-fractured—were analyzed under a normal gait scenario. The maximum von Mises and shear stresses for the normal femur were 17% and 19.8% while for intertrochanteric, subtrochanteric, and shaft fractures were 38.9% and 43.5%, 47.2% and 51.6% and 35.6% and 38.7% respectively, compared to the yield strengths of LAE442 Mg alloy (193 MPa compressive, 90.8 MPa shear). The total deformations were also within a normal range of up to 2 mm, indicating that the alloy is fairly suitable for femoral load-bearing during a normal gait cycle.

HITEC University (PK)
Openalex Percentile: Top 26%
Hip and Femur Fractures
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.