High-Order Piezoelectric Micromachined Ultrasonic Transducer With Piezoelectric Layer Trench for Ultrasound Imaging

This letter presents a high-order PZT PMUT (HO-PMUT) array with trenched piezoelectric layer operating at 1.78 MHz. This high-order and trench design boosts the resonant frequency to MHz without reducing the radius, while increasing vibration amplitude and Q factor compared to fundamental PMUTs. Through optimized dual electrodes, the array achieved a normalized transmitting sensitivity (TS) of 19 kPa*mm*V<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>*mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup>. We demonstrated its pioneering application in ultrasound imaging by mechanically scanning a steel sample and generating a B-mode image with 7.34 dB SNR, showcasing its superior acoustic performance and potential for portable ultrasonic imaging devices. [2025-0027]

Authors

Institutions

Publication Details

Journal
Journal of Microelectromechanical Systems
Published
2025-05-16
DOI
https://doi.org/10.1109/jmems.2025.3560146
Citations
4
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
2.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Order Piezoelectric Micromachined Ultrasonic Transducer With Piezoelectric Layer Trench for Ultrasound Imaging

Junxiang Cai, Yiwei Wang, Tao Wu
4 citations
Journal of Microelectromechanical Systems
Photoacoustic and Ultrasonic Imaging
2.70
article

High-Order Piezoelectric Micromachined Ultrasonic Transducer With Piezoelectric Layer Trench for Ultrasound Imaging

Junxiang Cai, Yiwei Wang, Tao Wu
article en
4 citations

Abstract

This letter presents a high-order PZT PMUT (HO-PMUT) array with trenched piezoelectric layer operating at 1.78 MHz. This high-order and trench design boosts the resonant frequency to MHz without reducing the radius, while increasing vibration amplitude and Q factor compared to fundamental PMUTs. Through optimized dual electrodes, the array achieved a normalized transmitting sensitivity (TS) of 19 kPa*mm*V<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>*mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup>. We demonstrated its pioneering application in ultrasound imaging by mechanically scanning a steel sample and generating a B-mode image with 7.34 dB SNR, showcasing its superior acoustic performance and potential for portable ultrasonic imaging devices. [2025-0027]

Journal of Microelectromechanical SystemsVol. 34(4)
ShanghaiTech University (CN)
Affordable and clean energy
Openalex Percentile: Top 10%
Photoacoustic and Ultrasonic Imaging
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.