The Impact of Receiver Geometry with Nanofluid on the Performance of a Fresnel Collector

Solar energy devices have acquired growing attention to developing friendly-environment techniques. Linear Fresnel collector is preferred due to its low thermal losses. The present work numerically studied the impact of a linear Fresnel receiver geometry and utilizing TiO2 on the performance of the collector. Circular and isosceles receivers were investigated. Three TiO2 volume fractions were utilized: 0%, 2%, and 4%. The tested Reynolds number range was between 100 and 900. COMSOL Multiphysics 6.1, i.e., based on the Finite Element method, was used to solve the present problem. The circular receiver had significantly better comprehensive evaluation criteria than the triangular. The Nusselt number improved by 2.64% at Reynolds number 900 as 4% TiO2 was added to the pure water. The triangular receiver friction factor was up to 16.7% lower than the circular for Reynolds number<300 and 4% TiO2.

Authors

Institutions

Publication Details

Journal
Tikrit Journal of Engineering Sciences
Published
2025-03-24
DOI
https://doi.org/10.25130/tjes.32.1.19
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Receiver Geometry with Nanofluid on the Performance of a Fresnel Collector

Samer M. Khalaf, Hussam S. Dheyab, Kamaruzzaman Sopian, Manar Al-Jethelah et al.
Tikrit Journal of Engineering Sciences
Solar Thermal and Photovoltaic Systems
article

The Impact of Receiver Geometry with Nanofluid on the Performance of a Fresnel Collector

Samer M. Khalaf, Hussam S. Dheyab, Kamaruzzaman Sopian, Manar Al-Jethelah, Khairul Habib
article en

Abstract

Solar energy devices have acquired growing attention to developing friendly-environment techniques. Linear Fresnel collector is preferred due to its low thermal losses. The present work numerically studied the impact of a linear Fresnel receiver geometry and utilizing TiO2 on the performance of the collector. Circular and isosceles receivers were investigated. Three TiO2 volume fractions were utilized: 0%, 2%, and 4%. The tested Reynolds number range was between 100 and 900. COMSOL Multiphysics 6.1, i.e., based on the Finite Element method, was used to solve the present problem. The circular receiver had significantly better comprehensive evaluation criteria than the triangular. The Nusselt number improved by 2.64% at Reynolds number 900 as 4% TiO2 was added to the pure water. The triangular receiver friction factor was up to 16.7% lower than the circular for Reynolds number<300 and 4% TiO2.

Tikrit Journal of Engineering SciencesVol. 32(1)
University of Tikrit (IQ)
Openalex Percentile: Top 94%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Impact of Receiver Geometry with Nanofluid on the Performance of a Fresnel Collector — Samer M. Khalaf, Hussam S. Dheyab, et al. · Tikrit Journal of Engineering Sciences (2025) | TGRS Research Map | TGRS