Development and Preclinical Testing of a Rapid, High-Volume, Auto-Injector for Subcutaneous Administration with Recombinant Human Hyaluronidase

Handheld auto-injectors (AIs) provide a convenient method for subcutaneous (SC) administration of therapeutics in clinical settings or at home via a caregiver or self-administration. However, AIs have been limited to low volumes (< 2 mL), partly due to hyaluronan (HA), a glycosaminoglycan that acts as a barrier to bulk fluid flow in the SC tissue. Recombinant human hyaluronidase PH20 (rHuPH20) is an enzyme that temporarily depolymerizes HA to facilitate the dispersion of SC-administered therapeutics and may enhance the use of AIs capable of delivering high volumes. These studies detail the development and preclinical testing of a novel high-volume AI (HVAI) that successfully delivered 10 mL of a representative macromolecule (immune globulin; Ig) co-administered with rHuPH20 in ≤ 30 s (s) in a miniature pig model. Testing of a surrogate AI informed the development of a novel, clinically-ready prototype HVAI. HVAI injections of Ig co-administered with 2,000 U/mL rHuPH20 improved injection site outcomes (back-leakage, bleb size, swelling, induration) and yielded up to 30% faster injection times compared with injections of Ig alone. In a mock clinical study that replicated clinical settings, the HVAI delivered 10 mL of Ig with 4,000 U/mL rHuPH20 with mean (± standard error of the mean) injection durations of 19.8 s (± 0.5) using a thin-wall 25-gauge (G) needle and 30.0 s (± 1.1) using a standard 25G needle. The data presented here demonstrate the feasibility of the prototype HVAI for rapid, high-volume administration of a concentrated biologic with rHuPH20, and will inform future clinical testing.

Authors

Institutions

Publication Details

Journal
AAPS PharmSciTech
Published
2025-05-16
DOI
https://doi.org/10.1208/s12249-025-03116-5
Citations
1
Primary Topic
Advanced Drug Delivery Systems
Type
article
Field-Weighted Citation Impact
0.79

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Preclinical Testing of a Rapid, High-Volume, Auto-Injector for Subcutaneous Administration with Recombinant Human Hyaluronidase

Tara Nekoroski, Robert Connor, David W. Kang
1 citations
AAPS PharmSciTech
Advanced Drug Delivery Systems
0.79
article

Development and Preclinical Testing of a Rapid, High-Volume, Auto-Injector for Subcutaneous Administration with Recombinant Human Hyaluronidase

Tara Nekoroski, Robert Connor, David W. Kang
article en
1 citations

Abstract

Handheld auto-injectors (AIs) provide a convenient method for subcutaneous (SC) administration of therapeutics in clinical settings or at home via a caregiver or self-administration. However, AIs have been limited to low volumes (< 2 mL), partly due to hyaluronan (HA), a glycosaminoglycan that acts as a barrier to bulk fluid flow in the SC tissue. Recombinant human hyaluronidase PH20 (rHuPH20) is an enzyme that temporarily depolymerizes HA to facilitate the dispersion of SC-administered therapeutics and may enhance the use of AIs capable of delivering high volumes. These studies detail the development and preclinical testing of a novel high-volume AI (HVAI) that successfully delivered 10 mL of a representative macromolecule (immune globulin; Ig) co-administered with rHuPH20 in ≤ 30 s (s) in a miniature pig model. Testing of a surrogate AI informed the development of a novel, clinically-ready prototype HVAI. HVAI injections of Ig co-administered with 2,000 U/mL rHuPH20 improved injection site outcomes (back-leakage, bleb size, swelling, induration) and yielded up to 30% faster injection times compared with injections of Ig alone. In a mock clinical study that replicated clinical settings, the HVAI delivered 10 mL of Ig with 4,000 U/mL rHuPH20 with mean (± standard error of the mean) injection durations of 19.8 s (± 0.5) using a thin-wall 25-gauge (G) needle and 30.0 s (± 1.1) using a standard 25G needle. The data presented here demonstrate the feasibility of the prototype HVAI for rapid, high-volume administration of a concentrated biologic with rHuPH20, and will inform future clinical testing.

AAPS PharmSciTechVol. 26(5)
Halozyme Therapeutics (United States) (US)
Halozyme
Openalex Percentile: Top 28%
Advanced Drug Delivery Systems
0.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Preclinical Testing of a Rapid, High-Volume, Auto-Injector for Subcutaneous Administration with Recombinant Human Hyaluronidase — Tara Nekoroski, Robert Connor, et al. · AAPS PharmSciTech (2025) | TGRS Research Map | TGRS