Uncertainty evaluation of the caesium fountain primary frequency standard NIM6

Abstract A new caesium (Cs) fountain clock NIM6 has been developed at the National Institute of Metrology (NIM) in China, for which a comprehensive uncertainty evaluation is presented. A three-dimensional magneto-optical trap loading optical molasses is employed to obtain more cold atoms rapidly and efficiently with a tunable, uniform density distribution. A heat pipe surrounding the flight tube maintains a consistent and stable temperature within the interrogation region. Additionally, a Ramsey cavity with four azimuthally distribution feeds is utilized to mitigate distributed cavity phase shifts. The Cs fountain clock NIM6 achieves a short-term fractional frequency instability of 1.0 × 10 −13 τ −1/2 at high atomic density, and a typical overall fractional type-B uncertainty is estimated to be 2.2 × 10 −16 . Comparisons of frequency between the Cs fountain NIM6 and other Cs fountain primary frequency standards through Coordinated Universal Time have demonstrated an agreement within the stated uncertainties.

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-05-16
DOI
https://doi.org/10.1088/1681-7575/add9a7
Citations
3
Primary Topic
Advanced Frequency and Time Standards
Type
article
Field-Weighted Citation Impact
3.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty evaluation of the caesium fountain primary frequency standard NIM6

Shaoyang Dai, Nianfeng Liu, Yuzhuo Wang, Fang Fang et al.
3 citations
Metrologia
Advanced Frequency and Time Standards
3.74
article

Uncertainty evaluation of the caesium fountain primary frequency standard NIM6

Shaoyang Dai, Nianfeng Liu, Yuzhuo Wang, Fang Fang, Weiliang Chen, Fasong Zheng, Kun Liu
article en
3 citations

Abstract

Abstract A new caesium (Cs) fountain clock NIM6 has been developed at the National Institute of Metrology (NIM) in China, for which a comprehensive uncertainty evaluation is presented. A three-dimensional magneto-optical trap loading optical molasses is employed to obtain more cold atoms rapidly and efficiently with a tunable, uniform density distribution. A heat pipe surrounding the flight tube maintains a consistent and stable temperature within the interrogation region. Additionally, a Ramsey cavity with four azimuthally distribution feeds is utilized to mitigate distributed cavity phase shifts. The Cs fountain clock NIM6 achieves a short-term fractional frequency instability of 1.0 × 10 −13 τ −1/2 at high atomic density, and a typical overall fractional type-B uncertainty is estimated to be 2.2 × 10 −16 . Comparisons of frequency between the Cs fountain NIM6 and other Cs fountain primary frequency standards through Coordinated Universal Time have demonstrated an agreement within the stated uncertainties.

MetrologiaVol. 62(3)
Hefei University (CN), Academy of National Food and Strategic Reserves Administration (CN), National Institute of Metrology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 7%
Advanced Frequency and Time Standards
3.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Uncertainty evaluation of the caesium fountain primary frequency standard NIM6 — Shaoyang Dai, Nianfeng Liu, et al. · Metrologia (2025) | TGRS Research Map | TGRS