Bimetallic nanoprobe strip for the detection of human chorionic gonadotrophin in pregnancy

A novel nanotechnology-based approach was developed to enhance the accuracy and reliability of pregnancy detection to address the limitations of conventional kits like PregaNews, First Response, Accu-Clear, EPT (Error Proof Test), etc. which are based on the enzyme-linked immunosorbent assay (ELISA) method. Such conventional methods often suffer from complex procedures, low precision (33 %), cross-reactivity, and false positives. The developed new diagnostic platform employed a lateral flow assay-based gold-silver nanoprobe (GSNPs) system conjugated with 3-mercaptopropionate and monoclonal antibody 2 (mAb2), pre-dispersed on biodegradable Whatman filter paper and coupled with a smartphone-based application for the detection of hCG in pregnancy. The GSNPs with a particle size of 325.1 ± 0.64 nm, exhibited superior catalytic efficiency (0.29 to 0.37 nm) with significant specificity, and reliability in comparison to digital color analysis via RGB (red, green, blue) and HSV (hue, saturation, value) algorithmic model. This nanotechnology-based system demonstrated a wide detection range (0.4-2.4ng/mL) with a low limit of detection (LOD) at 0.79 ng/mL and limit of quantification (LOQ) at 9.67 ng/mL. The detection of pathological urine was consistent with the artificial urine sample at R<sup>2</sup>=0.9796 and showed linear relationship with saturation value (y = 5.1849x+3.4559). The biodegradable and portable diagnostic strip generates minimal bio-waste and offers eco-friendly disposal. This platform tool-based strip enables sensitive, rapid, user-friendly, and cost-effective detection of hCG compared to conventional pregnancy tests. The integration of bimetallic nanoprobe strip with smartphone technology ensures ease of accessibility, high precision, and environmental sustainability to increase the demand for such reliable and economic diagnostic tool.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2025-05-16
DOI
https://doi.org/10.1016/j.medengphy.2025.104354
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bimetallic nanoprobe strip for the detection of human chorionic gonadotrophin in pregnancy

Maithili Kantak, Pravin K. Shende
1 citations
Medical Engineering & Physics
Advanced biosensing and bioanalysis techniques
0.81
article

Bimetallic nanoprobe strip for the detection of human chorionic gonadotrophin in pregnancy

Maithili Kantak, Pravin K. Shende
article en
1 citations

Abstract

A novel nanotechnology-based approach was developed to enhance the accuracy and reliability of pregnancy detection to address the limitations of conventional kits like PregaNews, First Response, Accu-Clear, EPT (Error Proof Test), etc. which are based on the enzyme-linked immunosorbent assay (ELISA) method. Such conventional methods often suffer from complex procedures, low precision (33 %), cross-reactivity, and false positives. The developed new diagnostic platform employed a lateral flow assay-based gold-silver nanoprobe (GSNPs) system conjugated with 3-mercaptopropionate and monoclonal antibody 2 (mAb2), pre-dispersed on biodegradable Whatman filter paper and coupled with a smartphone-based application for the detection of hCG in pregnancy. The GSNPs with a particle size of 325.1 ± 0.64 nm, exhibited superior catalytic efficiency (0.29 to 0.37 nm) with significant specificity, and reliability in comparison to digital color analysis via RGB (red, green, blue) and HSV (hue, saturation, value) algorithmic model. This nanotechnology-based system demonstrated a wide detection range (0.4-2.4ng/mL) with a low limit of detection (LOD) at 0.79 ng/mL and limit of quantification (LOQ) at 9.67 ng/mL. The detection of pathological urine was consistent with the artificial urine sample at R<sup>2</sup>=0.9796 and showed linear relationship with saturation value (y = 5.1849x+3.4559). The biodegradable and portable diagnostic strip generates minimal bio-waste and offers eco-friendly disposal. This platform tool-based strip enables sensitive, rapid, user-friendly, and cost-effective detection of hCG compared to conventional pregnancy tests. The integration of bimetallic nanoprobe strip with smartphone technology ensures ease of accessibility, high precision, and environmental sustainability to increase the demand for such reliable and economic diagnostic tool.

Medical Engineering & PhysicsVol. 141(1)
Narsee Monjee Institute of Management Studies (IN), National Institute of Pharmaceutical Education and Research (IN), National Institute of Pharmaceutical Education and Research (IN)
Openalex Percentile: Top 28%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.