Experimental analysis of copper foam thicknesses and non-uniform configurations on the performance of direct absorption parabolic trough collectors

• Fabricated copper foams with four thicknesses and their impact on DAPTC efficiency. • Designed and fabricated two innovative copper foams with gradient pore density. • Thermal efficiency improved by up to 143.9% with increasing foam thickness. • Thermal efficiency improved by 136.2% with gradient foam and reduced pressure drop. • Achieved a PEC of 1.42 with 25% copper foam thickness. Enhancing the thermal efficiency of direct absorption parabolic trough collectors is a fundamental challenge in advancing solar energy technologies, as improved heat absorption directly impacts overall system performance. This study experimentally investigates the influence of copper porous foams on the thermal performance of a direct absorption parabolic trough collector, aiming to optimize efficiency by analyzing various porous foam configurations under varying inlet temperatures (20 °C, 30 °C, and 40 °C) and flow rates (20–120 Lph). Four foam thicknesses, representing 25 %, 50 %, 75 %, and 100 % of the absorber tube’s inner radius, were tested in full and semi-porous arrangements. Additionally, two innovative gradient foams with radially variable pore densities—one increasing and one decreasing—were developed and analyzed. The results indicated that increasing foam thickness enhanced thermal efficiency, with maximum improvements of 111.6 %, 125.5 %, 133.9 %, and 143.9 % for the 25 %, 50 %, 75 %, and 100 % configurations, respectively. The full-porous 100 % foam achieved the highest thermal efficiency of 51.3 % (at 20 °C, 120 Lph) and a maximum temperature difference of 15.3 °C (at 20 Lph), albeit with the highest friction factor. The semi-porous arrangement yielded maximum efficiencies of 37.6 % and 44.8 % for 25 % and 100 % foams, respectively. The performance evaluation criteria for the 25 % copper foam in both full and semi-porous arrangements exceeded one, reaching a peak of 1.42, indicating it as the optimal configuration. Notably, the gradient copper foam with radially increasing pore density achieved a thermal efficiency of 50.3 %, comparable to the full-porous 100 % foam, but with reduced pressure drop, resulting in superior performance evaluation criteria.

Authors

Publication Details

Journal
Energy Conversion and Management X
Published
2025-05-16
DOI
https://doi.org/10.1016/j.ecmx.2025.101064
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental analysis of copper foam thicknesses and non-uniform configurations on the performance of direct absorption parabolic trough collectors

Mahdi Moghimi, Mahdi Navidbakhsh, Iman Shahdad
1 links
Energy Conversion and Management X
Solar Thermal and Photovoltaic Systems
article

Experimental analysis of copper foam thicknesses and non-uniform configurations on the performance of direct absorption parabolic trough collectors

Mahdi Moghimi, Mahdi Navidbakhsh, Iman Shahdad
article en

Abstract

• Fabricated copper foams with four thicknesses and their impact on DAPTC efficiency. • Designed and fabricated two innovative copper foams with gradient pore density. • Thermal efficiency improved by up to 143.9% with increasing foam thickness. • Thermal efficiency improved by 136.2% with gradient foam and reduced pressure drop. • Achieved a PEC of 1.42 with 25% copper foam thickness. Enhancing the thermal efficiency of direct absorption parabolic trough collectors is a fundamental challenge in advancing solar energy technologies, as improved heat absorption directly impacts overall system performance. This study experimentally investigates the influence of copper porous foams on the thermal performance of a direct absorption parabolic trough collector, aiming to optimize efficiency by analyzing various porous foam configurations under varying inlet temperatures (20 °C, 30 °C, and 40 °C) and flow rates (20–120 Lph). Four foam thicknesses, representing 25 %, 50 %, 75 %, and 100 % of the absorber tube’s inner radius, were tested in full and semi-porous arrangements. Additionally, two innovative gradient foams with radially variable pore densities—one increasing and one decreasing—were developed and analyzed. The results indicated that increasing foam thickness enhanced thermal efficiency, with maximum improvements of 111.6 %, 125.5 %, 133.9 %, and 143.9 % for the 25 %, 50 %, 75 %, and 100 % configurations, respectively. The full-porous 100 % foam achieved the highest thermal efficiency of 51.3 % (at 20 °C, 120 Lph) and a maximum temperature difference of 15.3 °C (at 20 Lph), albeit with the highest friction factor. The semi-porous arrangement yielded maximum efficiencies of 37.6 % and 44.8 % for 25 % and 100 % foams, respectively. The performance evaluation criteria for the 25 % copper foam in both full and semi-porous arrangements exceeded one, reaching a peak of 1.42, indicating it as the optimal configuration. Notably, the gradient copper foam with radially increasing pore density achieved a thermal efficiency of 50.3 %, comparable to the full-porous 100 % foam, but with reduced pressure drop, resulting in superior performance evaluation criteria.

Energy Conversion and Management XVol. 27
Openalex Percentile: Top 94%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.