Analisis Gangguan Hubung Singkat pada Generator Menggunakan Relay Arus Lebih di PT. Oki Pulp and Paper

Generators are an important component in electrical generation. One of the disturbances that occurs in the generator is a short circuit fault. PT Oki Pulp and Paper has a Diesel Generator which is equipment that can be used as an alternative electrical generator to meet backup electricity needs, when a trip / shutdown occurs, the diesel generator will become backup power. The diesel generator observed is YCSR with a capacity of 3875 KVA/380 Volts. The purpose of this research is to analyse the Short Circuit Disturbance of Diesel Generator YCSR 3875 KVA and analyse the calculation of the time required for Over Current Protection on short circuit disturbance of Diesel Generator YCSR 3875 KVA. The research was conducted at the DG House of PT Oki Pulp and Paper in December 2024. The results of the short circuit fault analysis obtained are 17,042.40 A. The time required for the relay to disconnect the electricity during a short circuit is 4.09 seconds. The time obtained from the calculation is quite short, it can be seen that the short circuit fault that occurred was 17,042.40 A. To get the results of the relay working time, there is a calculation to find out how much TMS is determined through calculation, from the calculation getting the TMS result of 1,007 seconds. With TMS = 1.007 seconds, calculations are carried out to find the time required for the overcurrent relay to send a signal to the circuit breaker.

Authors

Institutions

Publication Details

Journal
Mars Jurnal Teknik Mesin Industri Elektro Dan Ilmu Komputer
Published
2025-04-23
DOI
https://doi.org/10.61132/mars.v3i2.757
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis Gangguan Hubung Singkat pada Generator Menggunakan Relay Arus Lebih di PT. Oki Pulp and Paper

Irine Kartika F, M. Saleh Al Amin, As’ad Mubarok, Yudi Irwansi
Mars Jurnal Teknik Mesin Industri Elektro Dan Ilmu Komputer
Engineering and Technology Innovations
article

Analisis Gangguan Hubung Singkat pada Generator Menggunakan Relay Arus Lebih di PT. Oki Pulp and Paper

Irine Kartika F, M. Saleh Al Amin, As’ad Mubarok, Yudi Irwansi
article en

Abstract

Generators are an important component in electrical generation. One of the disturbances that occurs in the generator is a short circuit fault. PT Oki Pulp and Paper has a Diesel Generator which is equipment that can be used as an alternative electrical generator to meet backup electricity needs, when a trip / shutdown occurs, the diesel generator will become backup power. The diesel generator observed is YCSR with a capacity of 3875 KVA/380 Volts. The purpose of this research is to analyse the Short Circuit Disturbance of Diesel Generator YCSR 3875 KVA and analyse the calculation of the time required for Over Current Protection on short circuit disturbance of Diesel Generator YCSR 3875 KVA. The research was conducted at the DG House of PT Oki Pulp and Paper in December 2024. The results of the short circuit fault analysis obtained are 17,042.40 A. The time required for the relay to disconnect the electricity during a short circuit is 4.09 seconds. The time obtained from the calculation is quite short, it can be seen that the short circuit fault that occurred was 17,042.40 A. To get the results of the relay working time, there is a calculation to find out how much TMS is determined through calculation, from the calculation getting the TMS result of 1,007 seconds. With TMS = 1.007 seconds, calculations are carried out to find the time required for the overcurrent relay to send a signal to the circuit breaker.

Mars Jurnal Teknik Mesin Industri Elektro Dan Ilmu KomputerVol. 3(2)
Universitas Palembang (ID), Universitas PGRI Palembang
Openalex Percentile: Top 91%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.