Activation of Persulfates Using Alkali-Modified Activated Coke to Promote Phenol Removal

Coke (AC) was modified and activated with sodium hydroxide (NaOH) and potassium hydroxide (KOH) to produce AC-Na and AC-K, respectively, and applied as a persulfate (PS) activator to promote phenol (Ph) removal in water. Under the given experimental conditions, compared to AC/PS (Ph removal effect was 77.09%), the Ph removal effects were 94.46% and 88.73% for AC-K/PS and AC-Na/PS, respectively. AC-K proved to be a more effective activator than AC-Na and was used for all the subsequent experiments. When PS/phenol molar ratio was 6.26:1:00, the initial system pH was 7 and the system temperature was 25 °C; the AC-K/PS system could effectively remove Ph (98.75%) from the simulated wastewater. After that, the stability of AC-K was verified. Electron paramagnetic resonance (EPR) and quenching analysis confirmed the hydroxyl free radical (•OH) to be predominant within this system. EPR combined with X-ray photoelectron spectroscopy (XPS), Fourier-transformed infrared (FTIR) spectroscopy, and Raman spectroscopy indicated that the sulfate radical (SO<sub>4</sub><sup>•-</sup>) and •OH were generated due to the defects in AC-K, thereby enhancing the PS activation potency of AC-K. Additionally, the radical quenching experiments showed that the superoxide (O<sub>2</sub><sup>-</sup>) radical is a key intermediate product promoting SO<sub>4</sub><sup>•-</sup> and •OH, which aided Ph removal. Both radical (SO<sub>4</sub><sup>•-</sup> and •OH) and non-radical (<sup>1</sup>O<sub>2</sub>) pathways were found to co-exist during the removal process. The Ph removal rate of the AC-K/PS system could still reach 29.50%, even after four repeated cycles. These results demonstrate that the unique AC-K/PS system has a potential removal effect on organic pollutants in water.

Authors

Institutions

Publication Details

Journal
Nanomaterials
Published
2025-05-15
DOI
https://doi.org/10.3390/nano15100744
Citations
2
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
1.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Activation of Persulfates Using Alkali-Modified Activated Coke to Promote Phenol Removal

Shuang Shi, Yan Zhang, Jianxiong Wei, Yang Chen et al.
2 citations
Nanomaterials
Advanced oxidation water treatment
1.63
article

Activation of Persulfates Using Alkali-Modified Activated Coke to Promote Phenol Removal

Shuang Shi, Yan Zhang, Jianxiong Wei, Yang Chen, Xingyu Zhang, Qiang Ma, Xiaoxue Wang, Hua-rui Hao
article en
2 citations

Abstract

Coke (AC) was modified and activated with sodium hydroxide (NaOH) and potassium hydroxide (KOH) to produce AC-Na and AC-K, respectively, and applied as a persulfate (PS) activator to promote phenol (Ph) removal in water. Under the given experimental conditions, compared to AC/PS (Ph removal effect was 77.09%), the Ph removal effects were 94.46% and 88.73% for AC-K/PS and AC-Na/PS, respectively. AC-K proved to be a more effective activator than AC-Na and was used for all the subsequent experiments. When PS/phenol molar ratio was 6.26:1:00, the initial system pH was 7 and the system temperature was 25 °C; the AC-K/PS system could effectively remove Ph (98.75%) from the simulated wastewater. After that, the stability of AC-K was verified. Electron paramagnetic resonance (EPR) and quenching analysis confirmed the hydroxyl free radical (•OH) to be predominant within this system. EPR combined with X-ray photoelectron spectroscopy (XPS), Fourier-transformed infrared (FTIR) spectroscopy, and Raman spectroscopy indicated that the sulfate radical (SO<sub>4</sub><sup>•-</sup>) and •OH were generated due to the defects in AC-K, thereby enhancing the PS activation potency of AC-K. Additionally, the radical quenching experiments showed that the superoxide (O<sub>2</sub><sup>-</sup>) radical is a key intermediate product promoting SO<sub>4</sub><sup>•-</sup> and •OH, which aided Ph removal. Both radical (SO<sub>4</sub><sup>•-</sup> and •OH) and non-radical (<sup>1</sup>O<sub>2</sub>) pathways were found to co-exist during the removal process. The Ph removal rate of the AC-K/PS system could still reach 29.50%, even after four repeated cycles. These results demonstrate that the unique AC-K/PS system has a potential removal effect on organic pollutants in water.

NanomaterialsVol. 15(10)
Xi’an University (CN), Xi'an University of Technology (CN), Yulin University (CN), Shaanxi Yulin Energy Group (CN)
Education Department of Shaanxi Province, Shaanxi Provincial Science and Technology Department
Openalex Percentile: Top 17%
Advanced oxidation water treatment
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.