Calcium Ion Sensors with Unrivaled Stability and Selectivity Using a Bilayer Approach with Ionically Imprinted Nanocomposites

Calcium ion sensors are essential in clinical diagnosis, particularly in the management of chronic kidney disease. Multiple approaches have been developed to measure calcium ions, including flame photometry and ion chromatography. However, these devices are bulky and require specialized staff for operation and evaluation. The integration of all-solid-state ion-selective determination allows the design of miniaturized and low-cost sensing that can be used for the continuous monitoring of electrolytes. However, clinical use has been limited due to the low electrochemical stability and selectivity and high noise rate. This manuscript reports for the first time a novel miniaturized Ca<sup>2+</sup> ion-selective sensor, developed by using a two-layer nanocomposite thin film (5 µm thick). The device consists of functionalized silica nanoparticles embedded in a poly(vinyl chloride) (PVC) film, which was deposited onto a nanoporous zirconium silicate nanoparticle layer that served as the sensing surface. Systematic evaluation revealed that perfluoroalkane-functionalized silica nanoparticles enhanced Ca<sup>2+</sup> selectivity by minimizing K<sup>+</sup> diffusion, confirmed by both potentiometric measurements and quartz microbalance studies. The final sensor demonstrated a super-Nernstian sensitivity of 37 mV/Log[Ca<sup>2+</sup>], a low signal drift of 28 µV/s, a limit of detection of 1 µM, and exceptional selectivity against Na<sup>+</sup>, K<sup>+</sup>, and Mg<sup>2+</sup> ions. Long-term testing showed stable performance over three months of continuous operation. Clinical testing was conducted on patients with chronic kidney disease. An accurate real-time monitoring of electrolyte dynamics in dialysate samples was observed, where final concentrations matched those observed in physiological conditions.

Authors

Institutions

Publication Details

Journal
Nanomaterials
Published
2025-05-15
DOI
https://doi.org/10.3390/nano15100741
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calcium Ion Sensors with Unrivaled Stability and Selectivity Using a Bilayer Approach with Ionically Imprinted Nanocomposites

Roohi Chhabra, Xun Cao, Antonio Ruiz-Gonzalez, Kwang‐Leong Choy et al.
2 citations
Nanomaterials
Analytical Chemistry and Sensors
1.47
article

Calcium Ion Sensors with Unrivaled Stability and Selectivity Using a Bilayer Approach with Ionically Imprinted Nanocomposites

Roohi Chhabra, Xun Cao, Antonio Ruiz-Gonzalez, Kwang‐Leong Choy, Yizhong Huang, Andrew Davenport
article en
2 citations

Abstract

Calcium ion sensors are essential in clinical diagnosis, particularly in the management of chronic kidney disease. Multiple approaches have been developed to measure calcium ions, including flame photometry and ion chromatography. However, these devices are bulky and require specialized staff for operation and evaluation. The integration of all-solid-state ion-selective determination allows the design of miniaturized and low-cost sensing that can be used for the continuous monitoring of electrolytes. However, clinical use has been limited due to the low electrochemical stability and selectivity and high noise rate. This manuscript reports for the first time a novel miniaturized Ca<sup>2+</sup> ion-selective sensor, developed by using a two-layer nanocomposite thin film (5 µm thick). The device consists of functionalized silica nanoparticles embedded in a poly(vinyl chloride) (PVC) film, which was deposited onto a nanoporous zirconium silicate nanoparticle layer that served as the sensing surface. Systematic evaluation revealed that perfluoroalkane-functionalized silica nanoparticles enhanced Ca<sup>2+</sup> selectivity by minimizing K<sup>+</sup> diffusion, confirmed by both potentiometric measurements and quartz microbalance studies. The final sensor demonstrated a super-Nernstian sensitivity of 37 mV/Log[Ca<sup>2+</sup>], a low signal drift of 28 µV/s, a limit of detection of 1 µM, and exceptional selectivity against Na<sup>+</sup>, K<sup>+</sup>, and Mg<sup>2+</sup> ions. Long-term testing showed stable performance over three months of continuous operation. Clinical testing was conducted on patients with chronic kidney disease. An accurate real-time monitoring of electrolyte dynamics in dialysate samples was observed, where final concentrations matched those observed in physiological conditions.

NanomaterialsVol. 15(10)
Nanyang Technological University (SG), The Royal Free Hospital (GB), Duke Kunshan University (CN), University College London (GB)
Openalex Percentile: Top 19%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.