Effect of Centrifugation Speed and Blood Tubes with Different Contents on Certain Serum/Plasma Biochemical Parameters in Cocks

This study was carried out to investigate the effect of blood tubes with different anticoagulants and different spinning speed applications in the blood centrifuge on biochemical analyses. The study conducted with a total of 16 Gerze cocks, a native breed of Türkiye. In the first part of the study, 8 roosters were slaughtered and the blood taken was transferred to lithium heparinized tubes only. Then, the blood was centrifuged at 3000, 4000 and 5000 rpm for 10 minutes. Blood samples were taken into plain-tubes, K3EDTA and lithium heparin tubes, and centrifuged at 3000 rpm for 10 minutes. The study results indicated that, centrifugation speed had no statistically significant effect on the levels of plasma glucose (p = 0,691), triglyceride (p = 0,451), total cholesterol (p = 0,993), high-density lipoprotein [(HDL-cholesterol) (p = 0,917)], low-density lipoprotein [(LDL-cholesterol) (p = 0,990)], total protein (p = 0,860), inorganic phosphorus (p = 0,885), calcium (p = 0,980), amount of plasma (p = 0,903) and, aspartate aminotransferase activities [(AST) (p = 0,692)]. In the second part of the study 8 different cocks apart from first part of the study, were slaughtered and the blood taken into tubes with different contents as plain tubes (serum), lithium heparinized tubes (plasma) and K3EDTA tubes (plasma). Same parameters with first part of the study were investigated. The results showed that no statistical difference found between serum or plasma obtained from blood tubes with different contents (p˃0.05). Additionally, the calcium levels could not be analyzed with K3EDTA plasma. Consequently, we observed that centrifugation speeds up to 5000 rpm did not affect the parameters frequently investigated in scientific research and routine analysis in poultry Similarly, in the tube content experiment, no statistical difference was found in other parameters.

Authors

Publication Details

Journal
Research and practice in veterinary and animal science.
Published
2025-05-15
DOI
https://doi.org/10.69990/repvas.2025.2.2.2
Primary Topic
Animal Diversity and Health Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Centrifugation Speed and Blood Tubes with Different Contents on Certain Serum/Plasma Biochemical Parameters in Cocks

Halil Harman, Halil Yavuz, Abdullah Bilir
Research and practice in veterinary and animal science.
Animal Diversity and Health Studies
article

Effect of Centrifugation Speed and Blood Tubes with Different Contents on Certain Serum/Plasma Biochemical Parameters in Cocks

Halil Harman, Halil Yavuz, Abdullah Bilir
article en

Abstract

This study was carried out to investigate the effect of blood tubes with different anticoagulants and different spinning speed applications in the blood centrifuge on biochemical analyses. The study conducted with a total of 16 Gerze cocks, a native breed of Türkiye. In the first part of the study, 8 roosters were slaughtered and the blood taken was transferred to lithium heparinized tubes only. Then, the blood was centrifuged at 3000, 4000 and 5000 rpm for 10 minutes. Blood samples were taken into plain-tubes, K3EDTA and lithium heparin tubes, and centrifuged at 3000 rpm for 10 minutes. The study results indicated that, centrifugation speed had no statistically significant effect on the levels of plasma glucose (p = 0,691), triglyceride (p = 0,451), total cholesterol (p = 0,993), high-density lipoprotein [(HDL-cholesterol) (p = 0,917)], low-density lipoprotein [(LDL-cholesterol) (p = 0,990)], total protein (p = 0,860), inorganic phosphorus (p = 0,885), calcium (p = 0,980), amount of plasma (p = 0,903) and, aspartate aminotransferase activities [(AST) (p = 0,692)]. In the second part of the study 8 different cocks apart from first part of the study, were slaughtered and the blood taken into tubes with different contents as plain tubes (serum), lithium heparinized tubes (plasma) and K3EDTA tubes (plasma). Same parameters with first part of the study were investigated. The results showed that no statistical difference found between serum or plasma obtained from blood tubes with different contents (p˃0.05). Additionally, the calcium levels could not be analyzed with K3EDTA plasma. Consequently, we observed that centrifugation speeds up to 5000 rpm did not affect the parameters frequently investigated in scientific research and routine analysis in poultry Similarly, in the tube content experiment, no statistical difference was found in other parameters.

Research and practice in veterinary and animal science.
Openalex Percentile: Top 88%
Animal Diversity and Health Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.