A prospective non‐inferiority trial of pathogen reduced platelets compared to non‐pathogen reduced platelets for correction of viscoelastic platelet function testing in cardiac surgery
PRT-PLT transfusion results in lower responses in viscoelastic testing compared to PAS-PLT, although clinical outcomes with respect to blood component utilization and chest tube drainage were similar.
Authors
- Chintamani D. Atreya (ORCID: https://orcid.org/0000-0001-7393-2157)
- Aidaelis Martinez‐Hernandez
- Kenichi A. Tanaka (ORCID: https://orcid.org/0000-0002-5051-1365)
- Jackline Joy Lasola (ORCID: https://orcid.org/0000-0002-1287-6830)
- Juliana N. Marshall
- Magali J. Fontaine (ORCID: https://orcid.org/0000-0001-6731-9516)
- Parvez M. Lokhandwala (ORCID: https://orcid.org/0000-0003-3571-4102)
- Carlos H. Villa (ORCID: https://orcid.org/0000-0002-4632-4751)
- Søren M. Bentzen (ORCID: https://orcid.org/0000-0002-7444-7564)
- Reney Henderson (ORCID: https://orcid.org/0000-0003-4701-5827)
- Alexis Jones (ORCID: https://orcid.org/0000-0003-4955-7929)
- Min Zhan (ORCID: https://orcid.org/0000-0002-3776-7884)
Institutions
- University of Maryland, Baltimore (US)
- Center for Biologics Evaluation and Research (US)
- United States Food and Drug Administration (US)
- University of Oklahoma Health Sciences Center (US)
Publication Details
- Journal
- Transfusion
- Published
- 2025-05-15
- DOI
- https://doi.org/10.1111/trf.18281
- Primary Topic
- Blood transfusion and management
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- U.S. Department of Health and Human Services
- National Institutes of Health
- U.S. Food and Drug Administration
- Center of Excellence in Regulatory Science and Innovation
- National Institute of General Medical Sciences