Research on data-driven active distribution network operation status evaluation method

Due to the imbalanced nature of active distribution network operation status data, it is difficult to control the deviation between its evaluation results and the actual situation. Therefore, a data-driven active distribution network operation status evaluation method is proposed. Using a data-driven type-2 fuzzy algorithm to determine the interval range of clustering centers for active distribution network operation data, and using the IT2FKM clustering method to constrain the shift of clustering centers from minority to majority clusters in the case of imbalanced clusters. In the state evaluation stage, multi-source fusion is performed on the clustered data to evaluate the specific operating status from a voltage perspective. In the test results, the evaluation results of the design method have the highest fitting degree with the actual values, and the corresponding error is also stable within 0.1 p.u. Compared with the control group, it has a significant advantage.

Authors

Institutions

Publication Details

Published
2025-05-15
DOI
https://doi.org/10.1117/12.3069804
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on data-driven active distribution network operation status evaluation method

Yi Li, Yu Fan Edward Tan, Cheng Shu
Power Systems and Technologies
article

Research on data-driven active distribution network operation status evaluation method

Yi Li, Yu Fan Edward Tan, Cheng Shu
article en

Abstract

Due to the imbalanced nature of active distribution network operation status data, it is difficult to control the deviation between its evaluation results and the actual situation. Therefore, a data-driven active distribution network operation status evaluation method is proposed. Using a data-driven type-2 fuzzy algorithm to determine the interval range of clustering centers for active distribution network operation data, and using the IT2FKM clustering method to constrain the shift of clustering centers from minority to majority clusters in the case of imbalanced clusters. In the state evaluation stage, multi-source fusion is performed on the clustered data to evaluate the specific operating status from a voltage perspective. In the test results, the evaluation results of the design method have the highest fitting degree with the actual values, and the corresponding error is also stable within 0.1 p.u. Compared with the control group, it has a significant advantage.

Shanghai Electric (China) (CN)
Openalex Percentile: Top 91%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.