Droplet Digital PCR: A Powerful Tool for Accurate Quantification of Hepatitis D Virus RNA Levels and Verification of Detection Limits

Reliable quantification of hepatitis D virus (HDV) RNA levels is necessary for initiating and guiding antiviral treatment. The aim of this work is to develop and validate a digital PCR method for the accurate quantification of HDV RNA, including evaluation of its clinical accuracy, especially for low-concentrated clinical samples. The reverse transcription digital PCR (RT-dPCR) development followed the standard procedure, including primer design, determination of linearity, calculation of recovery and the intermediate precision of the RNA extraction kits, determination of the limit of detection (LOD) and quantification (LOQ), droplet size measurements, conversion factor, and uncertainty budget. The World Health Organisation (WHO)-HDV international standard was used for RT-dPCR development. Commutability of the new method was explored, comparing RT-dPCR with quantification assays applied in clinical routine using clinical plasma samples covering a range of HDV RNA concentrations. The conversion factor from copies/mL to IU/mL was 0.77. LOD and LOQ of the RT-dPCR were 0.7 copies/mL (0.56 IU/mL) and 10 copies/mL (8 IU/mL), respectively. When evaluating the qualitative results of the clinical HDV samples at low concentrations, 31% of the HDV clinical samples tested negative by RT-qPCR were tested positive by RT-dPCR. The RT-qPCR and RT-dPCR quantitative data showed a good correlation with a standard deviation of ±1.12 log IU/mL. RT-dPCR is an accurate method for HDV RNA quantification that may serve as a complement to RT-qPCR, especially when accurate detection is essential for decision making in clinical settings.

Authors

Institutions

Publication Details

Journal
Journal of Viral Hepatitis
Published
2025-05-15
DOI
https://doi.org/10.1111/jvh.70036
Citations
2
Primary Topic
Hepatitis C virus research
Type
article
Field-Weighted Citation Impact
2.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Droplet Digital PCR: A Powerful Tool for Accurate Quantification of Hepatitis D Virus RNA Levels and Verification of Detection Limits

Markus Cornberg, Birgit Bremer, Esmeralda Valiente, Benjamin Maasoumy et al.
2 citations
Journal of Viral Hepatitis
Hepatitis C virus research
2.64
article

Droplet Digital PCR: A Powerful Tool for Accurate Quantification of Hepatitis D Virus RNA Levels and Verification of Detection Limits

Markus Cornberg, Birgit Bremer, Esmeralda Valiente, Benjamin Maasoumy, Lisa Sandmann, A. Kummrow, Samreen Falak, Heiner H. Wedemeyer, Jörn Beheim-Schwarzbach, L. Windzio
article en
2 citations

Abstract

Reliable quantification of hepatitis D virus (HDV) RNA levels is necessary for initiating and guiding antiviral treatment. The aim of this work is to develop and validate a digital PCR method for the accurate quantification of HDV RNA, including evaluation of its clinical accuracy, especially for low-concentrated clinical samples. The reverse transcription digital PCR (RT-dPCR) development followed the standard procedure, including primer design, determination of linearity, calculation of recovery and the intermediate precision of the RNA extraction kits, determination of the limit of detection (LOD) and quantification (LOQ), droplet size measurements, conversion factor, and uncertainty budget. The World Health Organisation (WHO)-HDV international standard was used for RT-dPCR development. Commutability of the new method was explored, comparing RT-dPCR with quantification assays applied in clinical routine using clinical plasma samples covering a range of HDV RNA concentrations. The conversion factor from copies/mL to IU/mL was 0.77. LOD and LOQ of the RT-dPCR were 0.7 copies/mL (0.56 IU/mL) and 10 copies/mL (8 IU/mL), respectively. When evaluating the qualitative results of the clinical HDV samples at low concentrations, 31% of the HDV clinical samples tested negative by RT-qPCR were tested positive by RT-dPCR. The RT-qPCR and RT-dPCR quantitative data showed a good correlation with a standard deviation of ±1.12 log IU/mL. RT-dPCR is an accurate method for HDV RNA quantification that may serve as a complement to RT-qPCR, especially when accurate detection is essential for decision making in clinical settings.

Journal of Viral HepatitisVol. 32(6)
Physikalisch-Technische Bundesanstalt (DE), Medizinische Hochschule Hannover (DE), German Center for Infection Research (DE), Centre for Individualised Infection Medicine (DE)
European Association of National Metrology Institutes
Partnerships for the goals
Openalex Percentile: Top 11%
Hepatitis C virus research
2.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.