Inspection of lead aprons damage and evaluation of transmission rate with a 99mTc point-source

The intent was to inspect the damage to lead aprons worn by radiation practitioners and experimentally measure the relative transmission rates for undamaged and damaged aprons.Fluoroscopy and X-ray scans were made for 281 lead aprons collected from various departments of a large-capacity hospital. Dose rate measurements were obtained using an ionization chamber detector and 99m Tc point source. The transmission rates of the undamaged and damaged aprons were calculated and statistically evaluated. Big tears and crack, besides unknown ones named type 1, type 2, type 3, and type 4. Only 14.5 % aprons were counted as damaged and 32 % were used in the operation room unit. The transmission rate of the undamaged aprons was determined as 50.88 %. The transmission rates calculated for Big tears, cracks, type 1, type 2, type 3, and type 4 damages were 91.30 %, 62.75 %, 53.22 %, 58.10 %, 57.88 %, and 55.54 %, respectively. The study revealed that aside from common damages like tears and cracks, various damages and defects may significantly affect radiation transmission. This is to conclude that periodic fluoroscopy and X-ray scans are essential to explore such invisible damages and enhance radiation protection among radiation workers. Future studies are recommended to investigate preventive measures for apron damage.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-05-15
DOI
https://doi.org/10.1016/j.net.2025.103689
Primary Topic
Integrated Circuits and Semiconductor Failure Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inspection of lead aprons damage and evaluation of transmission rate with a 99mTc point-source

Mohammad Abuqbeitah, Nazenin İpek Işıkçı, Sinem Akyol, Nami Yeyin et al.
Nuclear Engineering and Technology
Integrated Circuits and Semiconductor Failure Analysis
article

Inspection of lead aprons damage and evaluation of transmission rate with a 99mTc point-source

Mohammad Abuqbeitah, Nazenin İpek Işıkçı, Sinem Akyol, Nami Yeyin, Mustafa Demir
article en

Abstract

The intent was to inspect the damage to lead aprons worn by radiation practitioners and experimentally measure the relative transmission rates for undamaged and damaged aprons.Fluoroscopy and X-ray scans were made for 281 lead aprons collected from various departments of a large-capacity hospital. Dose rate measurements were obtained using an ionization chamber detector and 99m Tc point source. The transmission rates of the undamaged and damaged aprons were calculated and statistically evaluated. Big tears and crack, besides unknown ones named type 1, type 2, type 3, and type 4. Only 14.5 % aprons were counted as damaged and 32 % were used in the operation room unit. The transmission rate of the undamaged aprons was determined as 50.88 %. The transmission rates calculated for Big tears, cracks, type 1, type 2, type 3, and type 4 damages were 91.30 %, 62.75 %, 53.22 %, 58.10 %, 57.88 %, and 55.54 %, respectively. The study revealed that aside from common damages like tears and cracks, various damages and defects may significantly affect radiation transmission. This is to conclude that periodic fluoroscopy and X-ray scans are essential to explore such invisible damages and enhance radiation protection among radiation workers. Future studies are recommended to investigate preventive measures for apron damage.

Nuclear Engineering and TechnologyVol. 57(10)
Palestine Polytechnic University (PS), Istanbul University-Cerrahpaşa (TR), Istanbul Technical University (TR), Istanbul University (TR)
Climate action
Openalex Percentile: Top 91%
Integrated Circuits and Semiconductor Failure Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Inspection of lead aprons damage and evaluation of transmission rate with a 99mTc point-source — Mohammad Abuqbeitah, Nazenin İpek Işıkçı, et al. · Nuclear Engineering and Technology (2025) | TGRS Research Map | TGRS