A numerical study of the heat-ventilation state of a portal tambour of a tunnel in winter

Numerical simulation of the heat–ventilation state of a portal tambour of a tunnel in winter is performed using the model of turbulent viscous heat-conducting compressible gas. The direct and reverse operating modes of heat–ventilation units (HVUs) located in the tambour are considered. The air intake and exhaust from the openings for the HVUs in the tambour occur at a 45° angle with respect to the plane of the wall. The following phenomena are taken into account when calculating the thermal state of the air mass in the tambour: air heating in the tambour due to operating HVUs; heat exchange between the air flowing from the outside into the tambour and the air in the tunnel; and heat exchange between the air flowing from the portal side into the tambour and the air in the tunnel. It is assumed that external cold air with a temperature of –43°C is flowing into the tambour at a volumetric flow rate of 100 m3 /s. The reverse operation mode of the HVUs ensures relatively uniform air flow along the height of the gate opening and does not allow cold air to penetrate from the outside into the tambour down to a depth of more than 10 m.

Authors

Publication Details

Journal
Vestnik Tomskogo gosudarstvennogo universiteta Matematika i mekhanika
Published
2025-01-01
DOI
https://doi.org/10.17223/19988621/93/12
Primary Topic
Underground infrastructure and sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A numerical study of the heat-ventilation state of a portal tambour of a tunnel in winter

Л. Л. Миньков, A. Yu. Krainov, A.A. Oberemok
Vestnik Tomskogo gosudarstvennogo universiteta Matematika i mekhanika
Underground infrastructure and sustainability
article

A numerical study of the heat-ventilation state of a portal tambour of a tunnel in winter

Л. Л. Миньков, A. Yu. Krainov, A.A. Oberemok
article en

Abstract

Numerical simulation of the heat–ventilation state of a portal tambour of a tunnel in winter is performed using the model of turbulent viscous heat-conducting compressible gas. The direct and reverse operating modes of heat–ventilation units (HVUs) located in the tambour are considered. The air intake and exhaust from the openings for the HVUs in the tambour occur at a 45° angle with respect to the plane of the wall. The following phenomena are taken into account when calculating the thermal state of the air mass in the tambour: air heating in the tambour due to operating HVUs; heat exchange between the air flowing from the outside into the tambour and the air in the tunnel; and heat exchange between the air flowing from the portal side into the tambour and the air in the tunnel. It is assumed that external cold air with a temperature of –43°C is flowing into the tambour at a volumetric flow rate of 100 m3 /s. The reverse operation mode of the HVUs ensures relatively uniform air flow along the height of the gate opening and does not allow cold air to penetrate from the outside into the tambour down to a depth of more than 10 m.

Vestnik Tomskogo gosudarstvennogo universiteta Matematika i mekhanika(93)
Openalex Percentile: Top 90%
Underground infrastructure and sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A numerical study of the heat-ventilation state of a portal tambour of a tunnel in winter — Л. Л. Миньков, A. Yu. Krainov, et al. · Vestnik Tomskogo gosudarstvennogo universiteta Matematika i mekhanika (2025) | TGRS Research Map | TGRS