Optimized and Validated Stability-Indicating RP-HPLC Method for Comprehensive Profiling of Process-Related Impurities and Stress-Induced Degradation Products in Rivaroxaban (XARELTO)®

An isocratic reverse-phase high-performance liquid chromatography (RP-HPLC) method, coupled with photodiode array detection (PDA), was developed for the identification and characterization of stress degradation products and an unknown process-related impurity of rivaroxaban in bulk drug form. Rivaroxaban, a selective and direct Factor Xa inhibitor, underwent forced degradation under hydrolytic (acidic, alkaline, and neutral), photolytic, thermal, and oxidative stress conditions, following the ICH's guidelines. The drug displayed significant susceptibility to acid, base, and oxidative environments leading to the formation of eleven degradation products. All degradation products, along with process impurities and Rivaroxaban, were effectively separated using a (4.6 × 250 mm, 5 µm) C18 Thermo ODS Hypersil column at ambient temperature. The mobile phase composed of acetonitrile and monobasic potassium phosphate (pH 2.9) in a 30:70 (<i>v</i>/<i>v</i>) ratio, with a flow rate of 1.0 mL/min, and detection was carried out at 249 nm. The LC-PDA method was validated in accordance with the ICH's guidelines and USP38-NF33, demonstrating specificity, linearity, accuracy, precision, and robustness. Recovery studies showed results within the range of 98.6-103.4%, with a % RSD LT 2%. The limits of detection (LOD) and quantitation (LOQ) for rivaroxaban were determined to be 0.30 ppm and 1.0 ppm, respectively. Stress studies confirmed that the degradation products did not interfere with rivaroxaban detection, establishing the method as stability-indicating. Specific impurities were identified, including impurity G at 2.79 min, impurity D at 3.50 min, impurity H at 5.32 min, impurity C at 6.14 min, impurity E at 8.36 min, impurity A at 9.03 min, and impurity F at 9.49 min. Additionally, several unknown impurities were observed at 3.20, 4.00, 4.59, and 4.77 min. Statistical evaluation confirmed the method's reliability, making it suitable for routine analysis, quality control of raw materials, formulations of varying strengths, dissolution studies, and bioequivalence assessments of rivaroxaban formulations.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2025-05-15
DOI
https://doi.org/10.3390/ijms26104744
Citations
2
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
1.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized and Validated Stability-Indicating RP-HPLC Method for Comprehensive Profiling of Process-Related Impurities and Stress-Induced Degradation Products in Rivaroxaban (XARELTO)®

Aktham Mestareehi
2 citations
International Journal of Molecular Sciences
Analytical Methods in Pharmaceuticals
1.50
article

Optimized and Validated Stability-Indicating RP-HPLC Method for Comprehensive Profiling of Process-Related Impurities and Stress-Induced Degradation Products in Rivaroxaban (XARELTO)®

Aktham Mestareehi
article en
2 citations

Abstract

An isocratic reverse-phase high-performance liquid chromatography (RP-HPLC) method, coupled with photodiode array detection (PDA), was developed for the identification and characterization of stress degradation products and an unknown process-related impurity of rivaroxaban in bulk drug form. Rivaroxaban, a selective and direct Factor Xa inhibitor, underwent forced degradation under hydrolytic (acidic, alkaline, and neutral), photolytic, thermal, and oxidative stress conditions, following the ICH's guidelines. The drug displayed significant susceptibility to acid, base, and oxidative environments leading to the formation of eleven degradation products. All degradation products, along with process impurities and Rivaroxaban, were effectively separated using a (4.6 × 250 mm, 5 µm) C18 Thermo ODS Hypersil column at ambient temperature. The mobile phase composed of acetonitrile and monobasic potassium phosphate (pH 2.9) in a 30:70 (<i>v</i>/<i>v</i>) ratio, with a flow rate of 1.0 mL/min, and detection was carried out at 249 nm. The LC-PDA method was validated in accordance with the ICH's guidelines and USP38-NF33, demonstrating specificity, linearity, accuracy, precision, and robustness. Recovery studies showed results within the range of 98.6-103.4%, with a % RSD LT 2%. The limits of detection (LOD) and quantitation (LOQ) for rivaroxaban were determined to be 0.30 ppm and 1.0 ppm, respectively. Stress studies confirmed that the degradation products did not interfere with rivaroxaban detection, establishing the method as stability-indicating. Specific impurities were identified, including impurity G at 2.79 min, impurity D at 3.50 min, impurity H at 5.32 min, impurity C at 6.14 min, impurity E at 8.36 min, impurity A at 9.03 min, and impurity F at 9.49 min. Additionally, several unknown impurities were observed at 3.20, 4.00, 4.59, and 4.77 min. Statistical evaluation confirmed the method's reliability, making it suitable for routine analysis, quality control of raw materials, formulations of varying strengths, dissolution studies, and bioequivalence assessments of rivaroxaban formulations.

International Journal of Molecular SciencesVol. 26(10)
Eugene Applebaum College of Pharmacy and Health Sciences (US), Wayne State University (US), Northeastern Illinois University (US), Isra University (JO)
Openalex Percentile: Top 20%
Analytical Methods in Pharmaceuticals
1.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.