Validity of Fitbit Inspire 2 in step count and distance measurement during treadmill walking

Background As technology evolves, the market for wearable physical activity monitors has expanded exponentially. As the user base of activity trackers grows, ensuring their accuracy and validity becomes increasingly crucial. However, research in this field remains limited. Methods This study evaluated the validity and accuracy of Fitbit in measuring step count and distance during standardised treadmill walking (5.5 km/h) for 30 minutes. Comparisons were made with the gold standard of manual step counting. ActiGraph data was collected and analysed simultaneously as a comparator. Results Thirty college students (16 males, 14 females) participated. Fitbit demonstrated excellent agreement with manually counted steps (intraclass correlation coefficients (ICCs) = 0.91, 95% CI: 0.81–0.96, p < 0.001). Overall Fitbit underestimated steps (mean absolute percentage error (MAPE) = 3.6 ± 0.03%) and distance travelled (MAPE = 10.5 ± 0.07%). Fitbit accuracy was higher in females (MAPE = 9.4 ± 0.07%) than males (MAPE = 11.4 ± 0.06%). A Bland-Altman plot between Fitbit and manual count presented less than 1% limit of agreement range (286.6 to −83.7). In contrast, ActiGraph lacked agreement and accuracy in step measurement in a controlled setting. Notably, gender differences may impact the accuracy in distance travelled but not in step counts recorded by Fitbit. Conclusions Our findings underscore the high validity and moderate-to-high accuracy of the Fitbit Inspire 2 in measuring step count relative to manual counting within controlled settings among young, healthy adults. However, Fitbit displayed low accuracy in measuring distance travelled compared to actual distances.

Authors

Institutions

Publication Details

Journal
Physiotherapy Practice and Research
Published
2025-05-15
DOI
https://doi.org/10.1177/22130683251337300
Primary Topic
Sports and Physical Education Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validity of Fitbit Inspire 2 in step count and distance measurement during treadmill walking

Cuisle Forde, Dympna Casey, Yat Wa Cheung, Sally Doherty et al.
Physiotherapy Practice and Research
Sports and Physical Education Research
article

Validity of Fitbit Inspire 2 in step count and distance measurement during treadmill walking

Cuisle Forde, Dympna Casey, Yat Wa Cheung, Sally Doherty, Leena Manyara, Hiu Lok Poon, Sean Twomey
article en

Abstract

Background As technology evolves, the market for wearable physical activity monitors has expanded exponentially. As the user base of activity trackers grows, ensuring their accuracy and validity becomes increasingly crucial. However, research in this field remains limited. Methods This study evaluated the validity and accuracy of Fitbit in measuring step count and distance during standardised treadmill walking (5.5 km/h) for 30 minutes. Comparisons were made with the gold standard of manual step counting. ActiGraph data was collected and analysed simultaneously as a comparator. Results Thirty college students (16 males, 14 females) participated. Fitbit demonstrated excellent agreement with manually counted steps (intraclass correlation coefficients (ICCs) = 0.91, 95% CI: 0.81–0.96, p < 0.001). Overall Fitbit underestimated steps (mean absolute percentage error (MAPE) = 3.6 ± 0.03%) and distance travelled (MAPE = 10.5 ± 0.07%). Fitbit accuracy was higher in females (MAPE = 9.4 ± 0.07%) than males (MAPE = 11.4 ± 0.06%). A Bland-Altman plot between Fitbit and manual count presented less than 1% limit of agreement range (286.6 to −83.7). In contrast, ActiGraph lacked agreement and accuracy in step measurement in a controlled setting. Notably, gender differences may impact the accuracy in distance travelled but not in step counts recorded by Fitbit. Conclusions Our findings underscore the high validity and moderate-to-high accuracy of the Fitbit Inspire 2 in measuring step count relative to manual counting within controlled settings among young, healthy adults. However, Fitbit displayed low accuracy in measuring distance travelled compared to actual distances.

Physiotherapy Practice and ResearchVol. 46(2)
Trinity College Dublin (IE)
Openalex Percentile: Top 84%
Sports and Physical Education Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.