The Effect of Lesion Length on Doppler Velocities Used Routinely to Determine Carotid Stenosis Cross-Sectional Severity

<b>Background/Objective</b>: Transcutaneous Doppler ultrasound is a fundamental tool in evaluating carotid stenosis cross-sectional severity (CS-CSS) in clinical practice because peak-systolic and end-diastolic velocities (PSV, EDV) increase with angiographic diameter stenosis. We tested the hypothesis that lesion length (LL) may affect PSV and EDV. <b>Methods</b>: CARUS (Carotid Artery IntravasculaR Ultrasound Study) prospectively enrolled 300 consecutive patients (age 47-83 years, 64.3% men, 63.3% symptomatic) with carotid stenosis ≥50% by Doppler ultrasound considered diagnostic (corelab analyst). We correlated stenosis LL (mm) and minimal lumen area (MLA, mm<sup>2</sup>) with PSV and EDV. <b>Results</b>: IVUS imaging (20 MHz Volcano/Philips) was uncomplicated. As IVUS probe forward/backward movement with systole/diastole ("jumping"-related artifact superimposed on motorized pullback) restrained LL (but not MLA) determination, LL measurement was angiographic. Final data set included 293 patients/stenoses (applicable to seven angiograms unsuitable for LL measurement). Irrespective of CS-CSS, a significant LL effect on PSV and EDV occurred with LL ≥ 7 mm (n = 224/293, i.e., 76.5% study patients/lesions; r = 0.38 and r = 0.35); for MLA irrespective of CS-CCS the coefficients were r = 0.49 (PSV) and r = 0.42 (EDV); <i>p</i> < 0.001 for all. For LL and MLA considered together, the correlations were stronger: r = 0.61 (PSV) and r = 0.54 (EDV); <i>p</i> < 0.0001 for both. Combined LL and MLA effect was represented by the following formulas: PSV = 0.31 × LL/MLA + 2.02 [m/s]; EDV = 0.12 × LL/MLA + 0.63 [m/s], enabling to correct the PSV (EDV)-based assessment of CS-CSS for the LL effect. <b>Conclusions</b>: This study provides, for the first time, systematic evidence that the length of carotid stenosis significantly affects lesional Doppler velocities. We established formulas incorporating the contribution of both stenosis length and its cross-sectional severity to PSV and EDV. We advocate including stenosis length measurement in duplex ultrasound reports when performing PSV (EDV)-based assessment of carotid cross-sectional stenosis severity.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-05-15
DOI
https://doi.org/10.3390/diagnostics15101259
Citations
1
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Lesion Length on Doppler Velocities Used Routinely to Determine Carotid Stenosis Cross-Sectional Severity

Krzysztof Żmudka, Łukasz Tekieli, Anna Kabłak-Ziembicka, Justyna Stefaniak et al.
1 citations
Diagnostics
Cerebrovascular and Carotid Artery Diseases
1.52
article

The Effect of Lesion Length on Doppler Velocities Used Routinely to Determine Carotid Stenosis Cross-Sectional Severity

Krzysztof Żmudka, Łukasz Tekieli, Anna Kabłak-Ziembicka, Justyna Stefaniak, Karolina Dzierwa, Piotr Paluszek, Adam Mazurek, Piotr Musiałek, Wladyslaw Dabrowski, Piotr Pieniążek
article en
1 citations

Abstract

<b>Background/Objective</b>: Transcutaneous Doppler ultrasound is a fundamental tool in evaluating carotid stenosis cross-sectional severity (CS-CSS) in clinical practice because peak-systolic and end-diastolic velocities (PSV, EDV) increase with angiographic diameter stenosis. We tested the hypothesis that lesion length (LL) may affect PSV and EDV. <b>Methods</b>: CARUS (Carotid Artery IntravasculaR Ultrasound Study) prospectively enrolled 300 consecutive patients (age 47-83 years, 64.3% men, 63.3% symptomatic) with carotid stenosis ≥50% by Doppler ultrasound considered diagnostic (corelab analyst). We correlated stenosis LL (mm) and minimal lumen area (MLA, mm<sup>2</sup>) with PSV and EDV. <b>Results</b>: IVUS imaging (20 MHz Volcano/Philips) was uncomplicated. As IVUS probe forward/backward movement with systole/diastole ("jumping"-related artifact superimposed on motorized pullback) restrained LL (but not MLA) determination, LL measurement was angiographic. Final data set included 293 patients/stenoses (applicable to seven angiograms unsuitable for LL measurement). Irrespective of CS-CSS, a significant LL effect on PSV and EDV occurred with LL ≥ 7 mm (n = 224/293, i.e., 76.5% study patients/lesions; r = 0.38 and r = 0.35); for MLA irrespective of CS-CCS the coefficients were r = 0.49 (PSV) and r = 0.42 (EDV); <i>p</i> < 0.001 for all. For LL and MLA considered together, the correlations were stronger: r = 0.61 (PSV) and r = 0.54 (EDV); <i>p</i> < 0.0001 for both. Combined LL and MLA effect was represented by the following formulas: PSV = 0.31 × LL/MLA + 2.02 [m/s]; EDV = 0.12 × LL/MLA + 0.63 [m/s], enabling to correct the PSV (EDV)-based assessment of CS-CSS for the LL effect. <b>Conclusions</b>: This study provides, for the first time, systematic evidence that the length of carotid stenosis significantly affects lesional Doppler velocities. We established formulas incorporating the contribution of both stenosis length and its cross-sectional severity to PSV and EDV. We advocate including stenosis length measurement in duplex ultrasound reports when performing PSV (EDV)-based assessment of carotid cross-sectional stenosis severity.

DiagnosticsVol. 15(10)
Jagiellonian University (PL), John Paul II Hospital (PL), Krakow Cardiovascular Research Institute (PL)
Uniwersytet Jagielloński w Krakowie, Ministry of Science and Higher Education of the Russian Federation
Openalex Percentile: Top 19%
Cerebrovascular and Carotid Artery Diseases
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.