Impedance Monitoring of Capacitively Coupled Plasma Based on the Vacuum Variable Capacitor Positions of Impedance Matching Unit

Plasma impedance monitoring in semiconductor manufacturing processes is performed using external sensors, such as voltage-current (VI) probes or directional couplers. Plasma chamber impedance measurements, conducted in non-50 Ω matched transmission lines, suffer from a lack of clean signals due to phase variations and the nonlinearity of plasma, thus, sensor calibration is required for each installment. In this study, we monitored plasma impedance in situ based on the position of the vacuum variable capacitor within the matching network, without employing an external VI probe. We observed changes in the matching position according to parameter variations and subsequently confirmed that the calculated plasma impedance also varied accordingly. This study demonstrates the feasibility of real-time plasma impedance monitoring under 50 Ω-matched conditions without the use of external sensors, thereby simplifying plasma diagnostics.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-05-15
DOI
https://doi.org/10.3390/electronics14102022
Citations
1
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impedance Monitoring of Capacitively Coupled Plasma Based on the Vacuum Variable Capacitor Positions of Impedance Matching Unit

Jiseok Lee, Sang Jeen Hong, H. Kim
1 citations
Electronics
Plasma Diagnostics and Applications
0.73
article

Impedance Monitoring of Capacitively Coupled Plasma Based on the Vacuum Variable Capacitor Positions of Impedance Matching Unit

Jiseok Lee, Sang Jeen Hong, H. Kim
article en
1 citations

Abstract

Plasma impedance monitoring in semiconductor manufacturing processes is performed using external sensors, such as voltage-current (VI) probes or directional couplers. Plasma chamber impedance measurements, conducted in non-50 Ω matched transmission lines, suffer from a lack of clean signals due to phase variations and the nonlinearity of plasma, thus, sensor calibration is required for each installment. In this study, we monitored plasma impedance in situ based on the position of the vacuum variable capacitor within the matching network, without employing an external VI probe. We observed changes in the matching position according to parameter variations and subsequently confirmed that the calculated plasma impedance also varied accordingly. This study demonstrates the feasibility of real-time plasma impedance monitoring under 50 Ω-matched conditions without the use of external sensors, thereby simplifying plasma diagnostics.

ElectronicsVol. 14(10)
Myongji University (KR)
National Research Council of Science and Technology
Openalex Percentile: Top 28%
Plasma Diagnostics and Applications
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.