The Use of Near-Infrared Spectroscopy for the Measurement of Abdominal Wall Tissue Oxygenation During Pneumoperitoneum in Laparoscopic Cholecystectomy

<b><i>Background:</i></b> Near-infrared spectroscopy (NIRS) has been developed to monitor cerebral oxygenation. Various studies have investigated its utility in measuring somatic tissue oxygenation and in noncardiac surgeries. <b><i>Aims:</i></b> The aim of this study was to determine the effect of pneumoperitoneum on the abdominal wall. <b><i>Study Design:</i></b> A prospective, case-control study. <b><i>Methods:</i></b> This study included 70 patients who had elective laparoscopic cholecystectomy. A regional oximetry sensor was placed on the anterior abdominal wall in all patients. Primary outcome measures included preoperative regional tissue saturation (rSO<sub>2</sub>) values. For secondary outcome measures, we recorded visual analogue scale (VAS) scores and tramadol usage at postoperative hours 2, 6, 12, and 24: intraoperative end-tidal CO<sub>2</sub> values; peripheral oxygen saturation (spo2); and abdominal subcutaneous fat tissue thickness. <b><i>Results:</i></b> The initial rSO<sub>2</sub> value (T1: 75.6 ± 6.64) was significantly higher than those measured at the predetermined time intervals during pneumoperitoneum (T4: 73.4 ± 6.3, T5: 68 ± 8.9, T6: 68 ± 8.9, T7: 66.6 ± 9.4, T8: 65.81 ± 10.2, T9: 65.6 ± 8.8) (<i>P</i> < .05). The mean change in rSO<sub>2</sub> between preoperative measurements (T1) and mid-pneumoperitoneum measurements (T8) was -12.9 ± 11%. This change was found to be negatively correlated with postoperative VAS scores and 24-hour tramadol consumption amounts. <b><i>Conclusion:</i></b> The results of the present study show that changes in abdominal wall tissue oxygenation during pneumoperitoneum can be measured with NIRS.

Authors

Institutions

Publication Details

Journal
Journal of Laparoendoscopic & Advanced Surgical Techniques
Published
2025-05-15
DOI
https://doi.org/10.1089/lap.2025.0062
Primary Topic
Abdominal Surgery and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Use of Near-Infrared Spectroscopy for the Measurement of Abdominal Wall Tissue Oxygenation During Pneumoperitoneum in Laparoscopic Cholecystectomy

Korgün Ökmen, Aycan Kurtarangil Doğan, Muharrem Uçar, Durdu Kahraman Yıldız et al.
Journal of Laparoendoscopic & Advanced Surgical Techniques
Abdominal Surgery and Complications
article

The Use of Near-Infrared Spectroscopy for the Measurement of Abdominal Wall Tissue Oxygenation During Pneumoperitoneum in Laparoscopic Cholecystectomy

Korgün Ökmen, Aycan Kurtarangil Doğan, Muharrem Uçar, Durdu Kahraman Yıldız, Sema Kalkan Uçar
article en

Abstract

<b><i>Background:</i></b> Near-infrared spectroscopy (NIRS) has been developed to monitor cerebral oxygenation. Various studies have investigated its utility in measuring somatic tissue oxygenation and in noncardiac surgeries. <b><i>Aims:</i></b> The aim of this study was to determine the effect of pneumoperitoneum on the abdominal wall. <b><i>Study Design:</i></b> A prospective, case-control study. <b><i>Methods:</i></b> This study included 70 patients who had elective laparoscopic cholecystectomy. A regional oximetry sensor was placed on the anterior abdominal wall in all patients. Primary outcome measures included preoperative regional tissue saturation (rSO<sub>2</sub>) values. For secondary outcome measures, we recorded visual analogue scale (VAS) scores and tramadol usage at postoperative hours 2, 6, 12, and 24: intraoperative end-tidal CO<sub>2</sub> values; peripheral oxygen saturation (spo2); and abdominal subcutaneous fat tissue thickness. <b><i>Results:</i></b> The initial rSO<sub>2</sub> value (T1: 75.6 ± 6.64) was significantly higher than those measured at the predetermined time intervals during pneumoperitoneum (T4: 73.4 ± 6.3, T5: 68 ± 8.9, T6: 68 ± 8.9, T7: 66.6 ± 9.4, T8: 65.81 ± 10.2, T9: 65.6 ± 8.8) (<i>P</i> < .05). The mean change in rSO<sub>2</sub> between preoperative measurements (T1) and mid-pneumoperitoneum measurements (T8) was -12.9 ± 11%. This change was found to be negatively correlated with postoperative VAS scores and 24-hour tramadol consumption amounts. <b><i>Conclusion:</i></b> The results of the present study show that changes in abdominal wall tissue oxygenation during pneumoperitoneum can be measured with NIRS.

Journal of Laparoendoscopic & Advanced Surgical TechniquesVol. 35(8)
Sağlık Bilimleri Üniversitesi (TR), S.B.Ü. Bursa Yüksek İhtisas Eğitim ve Araştırma Hastanesi (TR)
Openalex Percentile: Top 82%
Abdominal Surgery and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.