Simultaneous Multi-Adulterant Detection in Milk Using an In-house Developed Multiplexed Microfluidic Paper-Based Analytical Device (M-µPAD)

Abstract Milk adulteration poses a significant challenge in developing countries, impacting food safety and public health. This study introduces a multiplexed microfluidic paper-based analytical device (M-µPAD) for rapid and simultaneous detection of multiple milk adulterants. The M-µPAD, fabricated using readily available materials like filter paper and wax crayons, eliminates the need for specialized equipment. The device demonstrates linear relationships between colorimetric response and adulterant concentration for urea (10–200 mg/dL), starch (20-1000 mg/dL), and detergent (100–3000 mg/dL), with detection limits of 11.1, 22.4, and 120.8 mg/dL, respectively. Requiring only 40 µL of reagents and 80 µL of milk sample, the M-µPAD achieves over 95% accuracy and reproducibility with RSD values below 4%. This affordable, in-house fabricated platform offers a promising solution for milk quality assessment in resource-limited settings, addressing the need for accessible and efficient adulterant detection methods.

Authors

Institutions

Publication Details

Journal
Sensing and Imaging
Published
2025-05-15
DOI
https://doi.org/10.1007/s11220-025-00580-y
Citations
2
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Multi-Adulterant Detection in Milk Using an In-house Developed Multiplexed Microfluidic Paper-Based Analytical Device (M-µPAD)

Abdelkrim Khelif, Kashif Riaz, Muhammad Qasim Mehmood, Jannat Ahsan et al.
2 citations
Sensing and Imaging
Biosensors and Analytical Detection
1.35
article

Simultaneous Multi-Adulterant Detection in Milk Using an In-house Developed Multiplexed Microfluidic Paper-Based Analytical Device (M-µPAD)

Abdelkrim Khelif, Kashif Riaz, Muhammad Qasim Mehmood, Jannat Ahsan, Hudair Samad
article en
2 citations

Abstract

Abstract Milk adulteration poses a significant challenge in developing countries, impacting food safety and public health. This study introduces a multiplexed microfluidic paper-based analytical device (M-µPAD) for rapid and simultaneous detection of multiple milk adulterants. The M-µPAD, fabricated using readily available materials like filter paper and wax crayons, eliminates the need for specialized equipment. The device demonstrates linear relationships between colorimetric response and adulterant concentration for urea (10–200 mg/dL), starch (20-1000 mg/dL), and detergent (100–3000 mg/dL), with detection limits of 11.1, 22.4, and 120.8 mg/dL, respectively. Requiring only 40 µL of reagents and 80 µL of milk sample, the M-µPAD achieves over 95% accuracy and reproducibility with RSD values below 4%. This affordable, in-house fabricated platform offers a promising solution for milk quality assessment in resource-limited settings, addressing the need for accessible and efficient adulterant detection methods.

Sensing and ImagingVol. 26(1)
Information Technology University (PK), University of the Punjab (PK), Hamad bin Khalifa University (QA), Advanced Manufacturing Research Centre (GB), Istanbul Technical University (TR), University of Sheffield (GB)
Hamad Bin Khalifa University, Qatar National Library
Openalex Percentile: Top 20%
Biosensors and Analytical Detection
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.