Multi-objective Antlion optimizer for ring design in a 400kV Tension insulator

The key aspects for the reliability of the system include adequacy, resilience, redundancy, preventive maintenance and monitoring. The E-field in a high voltage insulator plays a major role in deciding the hydrophobicity of the material and initiation of partial discharge. Prevention of these situations can be avoided by ensuring proper design of the ring structures. The E-field in the polluted insulators is greatly affected compared to the virgin insulator due to the effect of surface conductivity and formation of dry bands. In this work, the efficacy of the optimized rings of 400kV insulator is verified under the contaminated conditions. The impact of electric field is analyzed for various thicknesses and orientation of the industrial pollutant. The optimized rings perform well under these contaminated conditions, successfully reducing the electric field below corona initiation levels.

Authors

Institutions

Publication Details

Published
2024-12-10
DOI
https://doi.org/10.1109/piicon63519.2024.10994989
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-objective Antlion optimizer for ring design in a 400kV Tension insulator

K. Usha, C Archana
3 links
Engineering Applied Research
article

Multi-objective Antlion optimizer for ring design in a 400kV Tension insulator

K. Usha, C Archana
article en

Abstract

The key aspects for the reliability of the system include adequacy, resilience, redundancy, preventive maintenance and monitoring. The E-field in a high voltage insulator plays a major role in deciding the hydrophobicity of the material and initiation of partial discharge. Prevention of these situations can be avoided by ensuring proper design of the ring structures. The E-field in the polluted insulators is greatly affected compared to the virgin insulator due to the effect of surface conductivity and formation of dry bands. In this work, the efficacy of the optimized rings of 400kV insulator is verified under the contaminated conditions. The impact of electric field is analyzed for various thicknesses and orientation of the industrial pollutant. The optimized rings perform well under these contaminated conditions, successfully reducing the electric field below corona initiation levels.

Sri Ramachandra Institute of Higher Education and Research (IN), Sri Sivasubramaniya Nadar College of Engineering (IN)
Science and Engineering Research Board
Affordable and clean energy
Openalex Percentile: Top 67%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.