Enhancing Backup Protection of the Transmission Network Under Stressed Conditions

The complex operating modes of the power transmission network have inadvertently increased the vulnerability of relay mal-function due to stressed conditions such as load encroachment and power swing etc. These conditions can trigger cascading outages, posing significant challenges in maintaining grid stability. Unintended operations of distance relays have been identified as a major factor in cascading outages and significant power system blackouts. To address this, enhancing backup protection to detect these stressed conditions has therefore become a top priority. A proposed backup protection scheme for detecting stressed conditions leverages the Rate of Change of Impedance Angle (ROCOIA) and effectively differentiates between internal and external faults using the Super-Imposed Current Angle Difference (SICAD). In contrast to conventional protection relays that isolate faulted components, this backup scheme initiates corrective actions to stabilize the power system under stressed conditions. It also unblocks the distance relay during faults, thereby ensuring the overall integrity and reliability of the system across various stressed scenarios.

Authors

Institutions

Publication Details

Published
2024-12-10
DOI
https://doi.org/10.1109/piicon63519.2024.10995034
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Backup Protection of the Transmission Network Under Stressed Conditions

Subhransu Ranjan Samantaray, K. Nageswara Rao Achary
Power Systems Fault Detection
article

Enhancing Backup Protection of the Transmission Network Under Stressed Conditions

Subhransu Ranjan Samantaray, K. Nageswara Rao Achary
article en

Abstract

The complex operating modes of the power transmission network have inadvertently increased the vulnerability of relay mal-function due to stressed conditions such as load encroachment and power swing etc. These conditions can trigger cascading outages, posing significant challenges in maintaining grid stability. Unintended operations of distance relays have been identified as a major factor in cascading outages and significant power system blackouts. To address this, enhancing backup protection to detect these stressed conditions has therefore become a top priority. A proposed backup protection scheme for detecting stressed conditions leverages the Rate of Change of Impedance Angle (ROCOIA) and effectively differentiates between internal and external faults using the Super-Imposed Current Angle Difference (SICAD). In contrast to conventional protection relays that isolate faulted components, this backup scheme initiates corrective actions to stabilize the power system under stressed conditions. It also unblocks the distance relay during faults, thereby ensuring the overall integrity and reliability of the system across various stressed scenarios.

Indian Institute of Technology Bhubaneswar (IN)
Climate action
Openalex Percentile: Top 62%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing Backup Protection of the Transmission Network Under Stressed Conditions — Subhransu Ranjan Samantaray, K. Nageswara Rao Achary · (2024) | TGRS Research Map | TGRS