A Simple Single Channel Type k Thermocouple Temperature Measurement Design

Thermocouples are widely used in the field of industrial production and are characterized by their simple structure, durability and wide range of applicable temperatures. For the multi-channel thermocouple temperature measurement circuit design is relatively complex, and most of the designs do not have a USB interface, which may be inconvenient to use. This paper proposes a simple single channel type k thermocouple thermometer with USB interface, which can read the temperature data directly through the host computer software. A thermostatic bath was used to test the design, and the experimental results showed that the accuracy of the design was better than 0.08%, which satisfied the design requirement of not less than 0.2% accuracy.

Authors

Institutions

Publication Details

Published
2025-02-28
DOI
https://doi.org/10.1109/iccece65250.2025.10985189
Citations
1
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simple Single Channel Type k Thermocouple Temperature Measurement Design

Ming Tao, Ruixuan Jiang, Renping Xie, Kai Ding
1 citations
Advanced Sensor Technologies Research
0.67
article

A Simple Single Channel Type k Thermocouple Temperature Measurement Design

Ming Tao, Ruixuan Jiang, Renping Xie, Kai Ding
article en
1 citations

Abstract

Thermocouples are widely used in the field of industrial production and are characterized by their simple structure, durability and wide range of applicable temperatures. For the multi-channel thermocouple temperature measurement circuit design is relatively complex, and most of the designs do not have a USB interface, which may be inconvenient to use. This paper proposes a simple single channel type k thermocouple thermometer with USB interface, which can read the temperature data directly through the host computer software. A thermostatic bath was used to test the design, and the experimental results showed that the accuracy of the design was better than 0.08%, which satisfied the design requirement of not less than 0.2% accuracy.

Dongguan University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 32%
Advanced Sensor Technologies Research
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.