Analysis of Partial Discharge Characteristics in Power Cables with Different Defects Under Power Frequency Voltage

This paper investigates the relationship between partial discharge (PD) behavior and applied voltage for different defect types in power cable insulation systems. A series of power frequency partial discharge tests were conducted. The study revealed that the partial discharge characteristics vary significantly based on the defect type and the applied voltage. For the main insulation knife-cut defect, both the magnitude and number of PD pulses increased steadily with rising voltage. Conversely, the sharp protrusion defect exhibited a decrease in PD activity at higher voltages due to a self-recovery phenomenon, while the conductive residue defect showed irregular PD behavior, reflecting the randomness of the discharge mechanism. These findings contribute to a better understanding of PD mechanisms in cable systems and provide insights for improving defect detection techniques and insulation material development.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10990817
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Partial Discharge Characteristics in Power Cables with Different Defects Under Power Frequency Voltage

Jingzhi Liu, Quanlei Qu, Hongyi Yang, Jianming Zhang et al.
Engineering Applied Research
article

Analysis of Partial Discharge Characteristics in Power Cables with Different Defects Under Power Frequency Voltage

Jingzhi Liu, Quanlei Qu, Hongyi Yang, Jianming Zhang, Jialin Wang, Zhidong Liu
article en

Abstract

This paper investigates the relationship between partial discharge (PD) behavior and applied voltage for different defect types in power cable insulation systems. A series of power frequency partial discharge tests were conducted. The study revealed that the partial discharge characteristics vary significantly based on the defect type and the applied voltage. For the main insulation knife-cut defect, both the magnitude and number of PD pulses increased steadily with rising voltage. Conversely, the sharp protrusion defect exhibited a decrease in PD activity at higher voltages due to a self-recovery phenomenon, while the conductive residue defect showed irregular PD behavior, reflecting the randomness of the discharge mechanism. These findings contribute to a better understanding of PD mechanisms in cable systems and provide insights for improving defect detection techniques and insulation material development.

North China Electric Power University (CN), State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources
Affordable and clean energy
Openalex Percentile: Top 67%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Partial Discharge Characteristics in Power Cables with Different Defects Under Power Frequency Voltage — Jingzhi Liu, Quanlei Qu, et al. · (2024) | TGRS Research Map | TGRS