Design, Implementation, and Performance Analysis of Average and Hysteresis Current Controlled Non-Isolated Boost PFC for Induction Heating

The presence of a filtered diode rectifier in the power stage of an Induction heater (IH) inevitably lowers the power factor and distorts the input current waveform of the utility. This leads to reduced efficiency and interferes with the functioning of other line-connected equipment. This paper attempts to improve the input power factor and regulate the line current harmonics within electromagnetic compatibility (EMC) standards. In this work, a non-isolated boost converter is operated in continuous conduction mode (CCM) to provide a precise and ripple-free DC voltage to the series resonant inverter of an induction heating system. A two-loop controller is designed with an outer voltage loop for regulating the power and an inner current loop for shaping the input current. The inductor current of the boost converter is controlled by Average current mode (ACM) control and Variable hysteresis current control (HCC) methods and their performance is gauged in terms of total harmonic distortion (THD) and power factor improvement. The control strategies are developed and implemented in an FPGA-based rapid prototyping tool and an induction heating system experimentally validates their performance. The results obtained show the superiority of the ACM (THD 2.4%,4.3%) over HCC (THD 3.02%,6.3%) in simulation and experimentally both.

Authors

Institutions

Publication Details

Published
2024-12-10
DOI
https://doi.org/10.1109/piicon63519.2024.10995134
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design, Implementation, and Performance Analysis of Average and Hysteresis Current Controlled Non-Isolated Boost PFC for Induction Heating

Sunil Poudyal, Teerath Das, Molay Roy
Induction Heating and Inverter Technology
article

Design, Implementation, and Performance Analysis of Average and Hysteresis Current Controlled Non-Isolated Boost PFC for Induction Heating

Sunil Poudyal, Teerath Das, Molay Roy
article en

Abstract

The presence of a filtered diode rectifier in the power stage of an Induction heater (IH) inevitably lowers the power factor and distorts the input current waveform of the utility. This leads to reduced efficiency and interferes with the functioning of other line-connected equipment. This paper attempts to improve the input power factor and regulate the line current harmonics within electromagnetic compatibility (EMC) standards. In this work, a non-isolated boost converter is operated in continuous conduction mode (CCM) to provide a precise and ripple-free DC voltage to the series resonant inverter of an induction heating system. A two-loop controller is designed with an outer voltage loop for regulating the power and an inner current loop for shaping the input current. The inductor current of the boost converter is controlled by Average current mode (ACM) control and Variable hysteresis current control (HCC) methods and their performance is gauged in terms of total harmonic distortion (THD) and power factor improvement. The control strategies are developed and implemented in an FPGA-based rapid prototyping tool and an induction heating system experimentally validates their performance. The results obtained show the superiority of the ACM (THD 2.4%,4.3%) over HCC (THD 3.02%,6.3%) in simulation and experimentally both.

National Institute of Technology Sikkim (IN)
Affordable and clean energy
Openalex Percentile: Top 71%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design, Implementation, and Performance Analysis of Average and Hysteresis Current Controlled Non-Isolated Boost PFC for Induction Heating — Sunil Poudyal, Teerath Das, et al. · (2024) | TGRS Research Map | TGRS