Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method

Positron emission tomography (PET) is the most sensitive <i>in vivo</i> molecular instrumentation. The image quality of PET can be significantly enhanced by incorporating time-of-flight (TOF) and depth-of-interaction (DOI) information. In this study, whole-body TOF-DOI PET detectors based on the dual-ended readout method were developed to simultaneously provide good TOF and DOI information. Each detector consisted of two 8 × 8 Hamamatsu S14161-3050-08 silicon photomultiplier (SiPM) arrays coupled to both ends of an 8 × 8 lutetium-yttrium oxyorthosilicate (LYSO) array with a thickness of 20 mm. Both the LYSO and SiPM arrays had a pitch of 3.2 mm, allowing each LYSO element to be coupled to two SiPM elements, one at each end of the crystal, to achieve the optimal timing resolution. Experimental results demonstrated that the detectors achieved a coincidence timing resolution of 234 ± 7 ps, an energy resolution of 13.7 ± 2.0%, and a DOI resolution of 2.6 ± 0.2 mm. These results suggest that the developed detectors are suitable for constructing whole-body TOF-DOI PET scanners with uniform spatial resolution across the entire field-of-view.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3570343
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method

Junwei Du, H.B. Wang, Jiahao Xie
2 citations
IEEE Transactions on Instrumentation and Measurement
Medical Imaging Techniques and Applications
2.72
article

Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method

Junwei Du, H.B. Wang, Jiahao Xie
article en
2 citations

Abstract

Positron emission tomography (PET) is the most sensitive <i>in vivo</i> molecular instrumentation. The image quality of PET can be significantly enhanced by incorporating time-of-flight (TOF) and depth-of-interaction (DOI) information. In this study, whole-body TOF-DOI PET detectors based on the dual-ended readout method were developed to simultaneously provide good TOF and DOI information. Each detector consisted of two 8 × 8 Hamamatsu S14161-3050-08 silicon photomultiplier (SiPM) arrays coupled to both ends of an 8 × 8 lutetium-yttrium oxyorthosilicate (LYSO) array with a thickness of 20 mm. Both the LYSO and SiPM arrays had a pitch of 3.2 mm, allowing each LYSO element to be coupled to two SiPM elements, one at each end of the crystal, to achieve the optimal timing resolution. Experimental results demonstrated that the detectors achieved a coincidence timing resolution of 234 ± 7 ps, an energy resolution of 13.7 ± 2.0%, and a DOI resolution of 2.6 ± 0.2 mm. These results suggest that the developed detectors are suitable for constructing whole-body TOF-DOI PET scanners with uniform spatial resolution across the entire field-of-view.

IEEE Transactions on Instrumentation and MeasurementVol. 74
University of California, Davis (US)
National Institutes of Health
Openalex Percentile: Top 11%
Medical Imaging Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.