Reliability assessment method for distribution system with distributed generations in anti-islanding operation mode

Large-scale distributed generation (DG) based on photovoltaic power is increasingly integrated into the distribution system, posing a significant threat to its power supply reliability due to its fluctuating output power influenced by weather conditions. Evaluating the reliability of the distribution system following the grid connection of DGs is crucial for guiding the planning of the distribution system and formulating protection strategies. This paper proposes a hybrid analysis method to assist in assessing the reliability of the distribution system under the anti-islanding operation mode of DGs. The reliability model of DGs is established using historical data and stochastic scenario generation techniques, considering the failures of system components. The reliability indicators of load points in the distribution system change based on the assessment of system adequacy, and the limitation of DG output power in the anti-islanding operation mode necessitates the removal of a fixed capacity of loads from the system. A detailed case study is presented in the end.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10990723
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability assessment method for distribution system with distributed generations in anti-islanding operation mode

Chong Gao, Xiaohui Ye, Qiang Luo, Lin Cheng et al.
Power Systems and Technologies
article

Reliability assessment method for distribution system with distributed generations in anti-islanding operation mode

Chong Gao, Xiaohui Ye, Qiang Luo, Lin Cheng, Xu Zhiheng, Wenbo Shao
article en

Abstract

Large-scale distributed generation (DG) based on photovoltaic power is increasingly integrated into the distribution system, posing a significant threat to its power supply reliability due to its fluctuating output power influenced by weather conditions. Evaluating the reliability of the distribution system following the grid connection of DGs is crucial for guiding the planning of the distribution system and formulating protection strategies. This paper proposes a hybrid analysis method to assist in assessing the reliability of the distribution system under the anti-islanding operation mode of DGs. The reliability model of DGs is established using historical data and stochastic scenario generation techniques, considering the failures of system components. The reliability indicators of load points in the distribution system change based on the assessment of system adequacy, and the limitation of DG output power in the anti-islanding operation mode necessitates the removal of a fixed capacity of loads from the system. A detailed case study is presented in the end.

China Southern Power Grid (China) (CN), Tsinghua University (CN)
Openalex Percentile: Top 72%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.