Analysis of the Transmission Characteristics of ±500kV Metal-Enclosed DC Potential Transformer

In order to obtain the transfer characteristic of DC potential transformer and improve the measurement accuracy, this paper takes the ±500kV metal-enclosed DC potential transformer as the research object and studies the changing rule of the transfer characteristic of ±500kV metal-enclosed DC potential transformer from typical aspects , such as production errors, stray parameters, ambient temperature, and output channel damage. The findings indicate that the errors in resistance production, ambient temperature variations, and the extent of output channel damage contribute to changes in resistance, which subsequently result in measurement errors for DC potential transformers. The relationship among these three factors and their impact on resistance change is as follows: output channel damage>ambient temperature>resistance production error. In the range of 18°C to 32°C, the temperature will not cause the measurement accuracy level of DC potential transformer to decrease. The stray capacitance mainly leads to the measuring error of AC voltage, that is, the measuring error of AC voltage increases about 0.4% when the stray capacitance increases by 5pF. The output channel mainly leads to the measurement error of direct flow, that is, as long as the output channel is damaged, the measurement result will not meet the standard requirements. When the resistance-capacitance matching relationship is destroyed and the system voltage changes, the DC voltage divider measurement results will have a short transition process, and the DC measurement error at the transition moment is seriously deviated from the normal value.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10991489
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Transmission Characteristics of ±500kV Metal-Enclosed DC Potential Transformer

H.C. Wen, Zaibin Jiao, Yuan Gao, Jianwei Wei et al.
3 links
Electric Power Systems and Control
article

Analysis of the Transmission Characteristics of ±500kV Metal-Enclosed DC Potential Transformer

H.C. Wen, Zaibin Jiao, Yuan Gao, Jianwei Wei, Gang Wang, Xiaokang Xu, Shichao Xie, Xiuyu Zhan
article en

Abstract

In order to obtain the transfer characteristic of DC potential transformer and improve the measurement accuracy, this paper takes the ±500kV metal-enclosed DC potential transformer as the research object and studies the changing rule of the transfer characteristic of ±500kV metal-enclosed DC potential transformer from typical aspects , such as production errors, stray parameters, ambient temperature, and output channel damage. The findings indicate that the errors in resistance production, ambient temperature variations, and the extent of output channel damage contribute to changes in resistance, which subsequently result in measurement errors for DC potential transformers. The relationship among these three factors and their impact on resistance change is as follows: output channel damage>ambient temperature>resistance production error. In the range of 18°C to 32°C, the temperature will not cause the measurement accuracy level of DC potential transformer to decrease. The stray capacitance mainly leads to the measuring error of AC voltage, that is, the measuring error of AC voltage increases about 0.4% when the stray capacitance increases by 5pF. The output channel mainly leads to the measurement error of direct flow, that is, as long as the output channel is damaged, the measurement result will not meet the standard requirements. When the resistance-capacitance matching relationship is destroyed and the system voltage changes, the DC voltage divider measurement results will have a short transition process, and the DC measurement error at the transition moment is seriously deviated from the normal value.

Energy Research Institute (CN), Henan Energy & Chemical Industry Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 72%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.