Effect of TSV – Keep Out Zone on BEOL Reliability of HBM3E

This study investigates the impact of the Keep-Out Zone (KOZ) distance on the BEOL reliability of HBM3E chips, presenting quantitative results not previously reported. While prior research has explored TSV-induced stress effects on FEOL and BEOL, the impact on metal layers has generally been considered minor. In this study, significant degradation in EM and IMD TDDB properties was observed as the KOZ distance decreased. The extent of degradation varied depending on KOZ distance and design layout but can be mitigated through process optimization and layout restrictions for adjacent metals/layers in HBM3E. Chip level tests confirmed that proper design and process control ensure minimal risk to the reliability of final chips. These findings suggest that mechanical stress induced by TSV and MLM tech shrink has begun to affect BEOL reliability in the KOZ region.

Authors

Institutions

Publication Details

Published
2025-03-30
DOI
https://doi.org/10.1109/irps48204.2025.10982993
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of TSV – Keep Out Zone on BEOL Reliability of HBM3E

Yonghui Eum, D.-H. Cho, Junho Song, Seung-Kwon Noh et al.
1 links
Orthopaedic implants and arthroplasty
article

Effect of TSV – Keep Out Zone on BEOL Reliability of HBM3E

Yonghui Eum, D.-H. Cho, Junho Song, Seung-Kwon Noh, Seungchan An, Jin‐Seok Kim, Junsung Kim, Taejoong Kim
article en

Abstract

This study investigates the impact of the Keep-Out Zone (KOZ) distance on the BEOL reliability of HBM3E chips, presenting quantitative results not previously reported. While prior research has explored TSV-induced stress effects on FEOL and BEOL, the impact on metal layers has generally been considered minor. In this study, significant degradation in EM and IMD TDDB properties was observed as the KOZ distance decreased. The extent of degradation varied depending on KOZ distance and design layout but can be mitigated through process optimization and layout restrictions for adjacent metals/layers in HBM3E. Chip level tests confirmed that proper design and process control ensure minimal risk to the reliability of final chips. These findings suggest that mechanical stress induced by TSV and MLM tech shrink has begun to affect BEOL reliability in the KOZ region.

SK Group (South Korea) (KR)
Openalex Percentile: Top 81%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of TSV – Keep Out Zone on BEOL Reliability of HBM3E — Yonghui Eum, D.-H. Cho, et al. · (2025) | TGRS Research Map | TGRS