Investigation on Steady-state Performance of 500 kV Single-core AC Submarine Cables under Different Grounding Methods

The investigation of grounding methods for long-distance AC submarine cables is of great importance for the safe operation of the cable system. This paper uses the multi-conductor analysis method to establish a computational model of a 500 kV AC submarine cable system with solid bonding grounding and multiple intermediate shorting point grounding. Subsequently, a matrix cascading algorithm is used to calculate and analyze the steady-state characteristics of the submarine cable system. The results show that the core current under the solid bonding method gradually decreases with the distance increase while the sheath current and armor current remain unchanged. Under the multiple intermediate short-circuit grounding method, the sheath-induced voltage significantly reduces, and the sheath current and armor current exhibit a jagged and staircase-like decrease, respectively.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10991586
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on Steady-state Performance of 500 kV Single-core AC Submarine Cables under Different Grounding Methods

Jialin Zhang, Enzhe Wang, Junkai Ge, Yong Yang et al.
Thermal Analysis in Power Transmission
article

Investigation on Steady-state Performance of 500 kV Single-core AC Submarine Cables under Different Grounding Methods

Jialin Zhang, Enzhe Wang, Junkai Ge, Yong Yang, Xiangrong Chen, N. C. Su
article en

Abstract

The investigation of grounding methods for long-distance AC submarine cables is of great importance for the safe operation of the cable system. This paper uses the multi-conductor analysis method to establish a computational model of a 500 kV AC submarine cable system with solid bonding grounding and multiple intermediate shorting point grounding. Subsequently, a matrix cascading algorithm is used to calculate and analyze the steady-state characteristics of the submarine cable system. The results show that the core current under the solid bonding method gradually decreases with the distance increase while the sheath current and armor current remain unchanged. Under the multiple intermediate short-circuit grounding method, the sheath-induced voltage significantly reduces, and the sheath current and armor current exhibit a jagged and staircase-like decrease, respectively.

Shanghai Electric (China) (CN), Zhejiang University (CN)
Science and Technology Project of State Grid
Openalex Percentile: Top 62%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.