Position Optimization of Non-contact Current Measurement Array for Overhead Transmission Lines

Given the existing challenges in the measurement of overhead transmission lines, achieving flexible collection and visualization of power information within the energy internet is essential. In this context, non-contact measurement of power data emerges as a critical solution to enhance efficiency and reliability in power monitoring systems. This paper proposes an effective approach for the non-contact current measurement using magnetic sensor array. The array is installed on the towers to collect the spatial magnetic field generated by the three-phase conductors and deduce the electrical information of the overhead conductors. In practical installation, the sensor array should be installed within the safe working area. Moreover, the installation location needs to be optimized to ensure the normal operation of the sensors and reduce measurement errors. This paper optimizes the installation location using a PSO algorithm. Case studies demonstrate that the sensor array at this optimized location improves the accuracy and stability of the inversion process significantly.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10991357
Primary Topic
Power Line Inspection Robots
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Position Optimization of Non-contact Current Measurement Array for Overhead Transmission Lines

Ziyang Ye, Fuchao Li, Yankai Xing, Jian Li et al.
Power Line Inspection Robots
article

Position Optimization of Non-contact Current Measurement Array for Overhead Transmission Lines

Ziyang Ye, Fuchao Li, Yankai Xing, Jian Li, Yalong Mai, D. Pang
article en

Abstract

Given the existing challenges in the measurement of overhead transmission lines, achieving flexible collection and visualization of power information within the energy internet is essential. In this context, non-contact measurement of power data emerges as a critical solution to enhance efficiency and reliability in power monitoring systems. This paper proposes an effective approach for the non-contact current measurement using magnetic sensor array. The array is installed on the towers to collect the spatial magnetic field generated by the three-phase conductors and deduce the electrical information of the overhead conductors. In practical installation, the sensor array should be installed within the safe working area. Moreover, the installation location needs to be optimized to ensure the normal operation of the sensors and reduce measurement errors. This paper optimizes the installation location using a PSO algorithm. Case studies demonstrate that the sensor array at this optimized location improves the accuracy and stability of the inversion process significantly.

University of Electronic Science and Technology of China (CN)
State Grid Corporation of China
Affordable and clean energy
Openalex Percentile: Top 71%
Power Line Inspection Robots
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.