Zero Mode Analysis of Single Pole to Ground Fault in the DC Distribution Networks

In this paper, based on the 32-node DC distribution network model, we analyze the zero-modulus nature of single pole to ground faults in DC distribution networks, and the specific research contents are as follows: establish a simulation model of DC distribution networks and analyze the zero mode nature of faults, compare and analyze the system structure and grounding mode of DC distribution networks, and based on the fault characteristics of DC distribution networks when a single pole to ground fault occurs, we use the phase-mode transformation method to decouple the transient components of faults into modal components, and analyze the single pole to ground fault and analyze the modal components of unipolar faults. Modal components are decoupled into modal components using the phase mode transformation method to analyze the unique zero mode nature of single pole to ground faults. The zero mode equivalent models of Modular Multilevel Converter (MMC) and DC/DC converter are constructed, and the zero mode equivalent impedance of the converter is deduced, and a 32-node DC distribution network simulation model is constructed in PSCAD/EMTDC for the simulation verification and analysis of the single pole to ground fault, and a single pole to ground fault simulation of the DC line is obtained. Fault characteristics of the single pole to ground fault.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10990733
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Zero Mode Analysis of Single Pole to Ground Fault in the DC Distribution Networks

Jing Bian, Xiaolu Shang, Wenpeng Liu, He Wang et al.
1 citations
HVDC Systems and Fault Protection
0.21
article

Zero Mode Analysis of Single Pole to Ground Fault in the DC Distribution Networks

Jing Bian, Xiaolu Shang, Wenpeng Liu, He Wang, Yuhan Pan
article en
1 citations

Abstract

In this paper, based on the 32-node DC distribution network model, we analyze the zero-modulus nature of single pole to ground faults in DC distribution networks, and the specific research contents are as follows: establish a simulation model of DC distribution networks and analyze the zero mode nature of faults, compare and analyze the system structure and grounding mode of DC distribution networks, and based on the fault characteristics of DC distribution networks when a single pole to ground fault occurs, we use the phase-mode transformation method to decouple the transient components of faults into modal components, and analyze the single pole to ground fault and analyze the modal components of unipolar faults. Modal components are decoupled into modal components using the phase mode transformation method to analyze the unique zero mode nature of single pole to ground faults. The zero mode equivalent models of Modular Multilevel Converter (MMC) and DC/DC converter are constructed, and the zero mode equivalent impedance of the converter is deduced, and a 32-node DC distribution network simulation model is constructed in PSCAD/EMTDC for the simulation verification and analysis of the single pole to ground fault, and a single pole to ground fault simulation of the DC line is obtained. Fault characteristics of the single pole to ground fault.

Northeast Electric Power University (CN), Jilin Electric Power Research Institute (China) (CN)
Climate action
Openalex Percentile: Top 43%
HVDC Systems and Fault Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Zero Mode Analysis of Single Pole to Ground Fault in the DC Distribution Networks — Jing Bian, Xiaolu Shang, et al. · (2024) | TGRS Research Map | TGRS