Automated Microbubble Discrimination in Ultrasound Localization Microscopy by Vision Transformer

Ultrasound localization microscopy (ULM) has revolutionized microvascular imaging by breaking the acoustic diffraction limit. However, different ULM workflows depend heavily on distinct prior knowledge, such as the impulse response and empirical selection of parameters (e.g., the number of microbubbles (MBs) per frame M), or the consistency of training-test dataset in deep learning (DL)-based studies. We hereby propose a general ULM pipeline that reduces priors. Our approach leverages a DL model that simultaneously distills MB signals and reduces speckles from every frame without estimating the impulse response and M. Our method features an efficient channel attention Vision Transformer (ViT) and a progressive learning strategy, enabling it to learn global information through training on progressively increasing patch sizes. Ample synthetic data were generated using the k-Wave toolbox to simulate various MB patterns, thus overcoming the deficiency of labeled data. The ViT output was further processed by a standard radial symmetry (RS) method for subpixel localization. Our method performed well on model-unseen public datasets: one in silico dataset with ground truth (GT) and four in vivo datasets of mouse tumor, rat brain, rat brain bolus, and rat kidney. Our pipeline outperformed conventional ULM, achieving higher positive predictive values (precision in DL, 0.88-0.41 versus 0.83-0.16) and improved accuracy (root-mean-square errors (RMSEs): 0.25- $0.14~\lambda $ versus 0.31- $0.13~\lambda $ ) across a range of signal-to-noise ratios (SNRs) from 60 to 10 dB. Our model could detect more vessels in diverse in vivo datasets while achieving comparable resolutions to the standard method. The proposed ViT-based model, seamlessly integrated with state-of-the-art downstream ULM steps, improved the overall ULM performance with no priors.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2025-05-15
DOI
https://doi.org/10.1109/tuffc.2025.3570496
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Microbubble Discrimination in Ultrasound Localization Microscopy by Vision Transformer

Renxian Wang, Wei-Ning Lee
1 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Photoacoustic and Ultrasonic Imaging
0.67
article

Automated Microbubble Discrimination in Ultrasound Localization Microscopy by Vision Transformer

Renxian Wang, Wei-Ning Lee
article en
1 citations

Abstract

Ultrasound localization microscopy (ULM) has revolutionized microvascular imaging by breaking the acoustic diffraction limit. However, different ULM workflows depend heavily on distinct prior knowledge, such as the impulse response and empirical selection of parameters (e.g., the number of microbubbles (MBs) per frame M), or the consistency of training-test dataset in deep learning (DL)-based studies. We hereby propose a general ULM pipeline that reduces priors. Our approach leverages a DL model that simultaneously distills MB signals and reduces speckles from every frame without estimating the impulse response and M. Our method features an efficient channel attention Vision Transformer (ViT) and a progressive learning strategy, enabling it to learn global information through training on progressively increasing patch sizes. Ample synthetic data were generated using the k-Wave toolbox to simulate various MB patterns, thus overcoming the deficiency of labeled data. The ViT output was further processed by a standard radial symmetry (RS) method for subpixel localization. Our method performed well on model-unseen public datasets: one in silico dataset with ground truth (GT) and four in vivo datasets of mouse tumor, rat brain, rat brain bolus, and rat kidney. Our pipeline outperformed conventional ULM, achieving higher positive predictive values (precision in DL, 0.88-0.41 versus 0.83-0.16) and improved accuracy (root-mean-square errors (RMSEs): 0.25- $0.14~\lambda $ versus 0.31- $0.13~\lambda $ ) across a range of signal-to-noise ratios (SNRs) from 60 to 10 dB. Our model could detect more vessels in diverse in vivo datasets while achieving comparable resolutions to the standard method. The proposed ViT-based model, seamlessly integrated with state-of-the-art downstream ULM steps, improved the overall ULM performance with no priors.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 72(8)
University of Hong Kong (HK)
Reduced inequalities
Openalex Percentile: Top 32%
Photoacoustic and Ultrasonic Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.