Rapid Estimation of CCT for GFM and GFL Inverters Integrated Systems Using the Direct Method

The integration of grid-forming (GFM) inverters can provide voltage and frequency support for the system and enhance system stability. However, existing transient stability analyses for GFM and grid-following (GFL) inverters integrated systems face challenges in rapidly estimating the stability domain, limiting their suitability for online applications. To address these issues, this paper quantifies the system’s transient stability domain using the critical clearing time (CCT). By considering the Q-V characteristics of the GFM and the power output characteristics of the GFL, the structure-preserving transient energy function (TEF) is derived based on the energy conservation law. Then, an improved iterative potential energy boundary surface (IPEBS) method is proposed to evaluate the CCT, which reduces estimation errors and prevents misjudgments while ensuring a conservative CCT estimation. Finally, simulations verify the method’s efficiency, accuracy, and conservatism.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10991892
Citations
1
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Estimation of CCT for GFM and GFL Inverters Integrated Systems Using the Direct Method

Yisheng Cai, Wenqi Huang, Yongzhi Zhou, Zhichao Gong
1 citations
Induction Heating and Inverter Technology
0.21
article

Rapid Estimation of CCT for GFM and GFL Inverters Integrated Systems Using the Direct Method

Yisheng Cai, Wenqi Huang, Yongzhi Zhou, Zhichao Gong
article en
1 citations

Abstract

The integration of grid-forming (GFM) inverters can provide voltage and frequency support for the system and enhance system stability. However, existing transient stability analyses for GFM and grid-following (GFL) inverters integrated systems face challenges in rapidly estimating the stability domain, limiting their suitability for online applications. To address these issues, this paper quantifies the system’s transient stability domain using the critical clearing time (CCT). By considering the Q-V characteristics of the GFM and the power output characteristics of the GFL, the structure-preserving transient energy function (TEF) is derived based on the energy conservation law. Then, an improved iterative potential energy boundary surface (IPEBS) method is proposed to evaluate the CCT, which reduces estimation errors and prevents misjudgments while ensuring a conservative CCT estimation. Finally, simulations verify the method’s efficiency, accuracy, and conservatism.

China Southern Power Grid (China) (CN), Zhejiang University (CN)
China Southern Power Grid
Affordable and clean energy
Openalex Percentile: Top 47%
Induction Heating and Inverter Technology
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.