Sensitivity Improvement of C4D Detectors by Adjusting Sinusoidal Integration With a Potentiometer

Capacitively coupled non-contact conductivity detectors (C4D) are a versatile and universal type of detector because they can detect cationic, anionic, fluorophore, non-fluorophore, fluorescent, or non-fluorescent compounds and can be adapted to capillary electrophoresis, liquid chromatography, or ion chromatography systems. In this study, a capacitive pseudo-bridge is adapted to a C4D detector to facilitate the adjustment to optimal levels of sensitivity using a potentiometer, which is adjusted by a screw that divides its resistance to perform a sinusoidal integration. When the C4D is manufactured, different capacitance values are obtained for the sensor due to variations in diameter, length, and void space, as well as a change in the resistivity of the mobile phase. All these changes can be adjusted using a potentiometer and an oscilloscope to visualize the optimum integration that occurs when a phase change is observed. To demonstrate the sensitivity of the C4D, analysis by High Performance Liquid Chromatography (HPLC), flow injection analysis (FIA), and ion chromatography (IC) produced a limit of detection of 0.98 μg/L for fluorides, 0.4 μg/L for sodium chloride, and 20 μg/L for fluorides, respectively. This novel adjustment of a potentiometer in a circuit of C4D detectors has not been proposed before for this kind of detector. A cosine output of the operational amplifier gives the maximum sensitivity of the capacitance to voltage converter.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3570598
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity Improvement of C4D Detectors by Adjusting Sinusoidal Integration With a Potentiometer

Ignacio Villanueva‐Fierro, Josué Ortiz‐Medina, Julio Cesar Ávila Grijalva, Verónica Loera‐Castañeda et al.
IEEE Access
Calibration and Measurement Techniques
article

Sensitivity Improvement of C4D Detectors by Adjusting Sinusoidal Integration With a Potentiometer

Ignacio Villanueva‐Fierro, Josué Ortiz‐Medina, Julio Cesar Ávila Grijalva, Verónica Loera‐Castañeda, Ismael Lares-Ásef, Ricardo González-López, María Myrna Solís-Oba
article en

Abstract

Capacitively coupled non-contact conductivity detectors (C4D) are a versatile and universal type of detector because they can detect cationic, anionic, fluorophore, non-fluorophore, fluorescent, or non-fluorescent compounds and can be adapted to capillary electrophoresis, liquid chromatography, or ion chromatography systems. In this study, a capacitive pseudo-bridge is adapted to a C4D detector to facilitate the adjustment to optimal levels of sensitivity using a potentiometer, which is adjusted by a screw that divides its resistance to perform a sinusoidal integration. When the C4D is manufactured, different capacitance values are obtained for the sensor due to variations in diameter, length, and void space, as well as a change in the resistivity of the mobile phase. All these changes can be adjusted using a potentiometer and an oscilloscope to visualize the optimum integration that occurs when a phase change is observed. To demonstrate the sensitivity of the C4D, analysis by High Performance Liquid Chromatography (HPLC), flow injection analysis (FIA), and ion chromatography (IC) produced a limit of detection of 0.98 μg/L for fluorides, 0.4 μg/L for sodium chloride, and 20 μg/L for fluorides, respectively. This novel adjustment of a potentiometer in a circuit of C4D detectors has not been proposed before for this kind of detector. A cosine output of the operational amplifier gives the maximum sensitivity of the capacitance to voltage converter.

IEEE AccessVol. 13
Universidad Autónoma de Tlaxcala (MX), Durango Institute of Technology (MX)
Affordable and clean energy
Openalex Percentile: Top 86%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensitivity Improvement of C4D Detectors by Adjusting Sinusoidal Integration With a Potentiometer — Ignacio Villanueva‐Fierro, Josué Ortiz‐Medina, et al. · IEEE Access (2025) | TGRS Research Map | TGRS