A Transformer Approach to Identifying False Data Injection Attacks

The smart grid is vulnerable to multiple cyberattacks, with false data injection attacks (FDIA) being particularly concerning, as they can evade conventional bad data detection (BDD) systems and disrupt power grid operations. Given the nonlinear nature of state estimation and grid data, along with the temporal continuity of state data, this study introduces a Transformer-based model for detecting FDIA. It utilizes the Hilbert-Huang Transform (HHT) to capture precise time-frequency characteristics from power system time-series data. These features are input into the Transformer, where multi-head attention captures long-range dependencies and improves recognition of complex grid patterns. The application of this technique on the IEEE 14-bus system demonstrates its capability to effectively recognize abnormal patterns with high accuracy. In addition, a basic sensitivity analysis of the control parameters was undertaken.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10990711
Primary Topic
Advanced Malware Detection Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Transformer Approach to Identifying False Data Injection Attacks

Huan Pan, Hu Li, Jiayi Jin, Mengna Sun
Advanced Malware Detection Techniques
article

A Transformer Approach to Identifying False Data Injection Attacks

Huan Pan, Hu Li, Jiayi Jin, Mengna Sun
article en

Abstract

The smart grid is vulnerable to multiple cyberattacks, with false data injection attacks (FDIA) being particularly concerning, as they can evade conventional bad data detection (BDD) systems and disrupt power grid operations. Given the nonlinear nature of state estimation and grid data, along with the temporal continuity of state data, this study introduces a Transformer-based model for detecting FDIA. It utilizes the Hilbert-Huang Transform (HHT) to capture precise time-frequency characteristics from power system time-series data. These features are input into the Transformer, where multi-head attention captures long-range dependencies and improves recognition of complex grid patterns. The application of this technique on the IEEE 14-bus system demonstrates its capability to effectively recognize abnormal patterns with high accuracy. In addition, a basic sensitivity analysis of the control parameters was undertaken.

Ningxia University (CN)
Openalex Percentile: Top 67%
Advanced Malware Detection Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.