Analysis of Cascading Failures in Power Cyber-Physical Systems Under Typhoon Conditions

Given the high coupling of cyber-physical systems in modern power grids, cascading failures are susceptible to natural disasters like typhoons, often leading to widespread blackouts. This study establishes a cascading failure analysis model tailored to typhoon scenarios to assess power CPS vulnerability under extreme weather. First, a typhoon disaster model, based on the Batts model, is constructed to evaluate impacts on transmission lines and initiate failure scenarios. Next, a cascading failure model for power CPS is proposed to simulate failure propagation, followed by simulations analyzing CPS vulnerability under typhoon conditions and assessing physical factors in failure spread. Results underscore the importance of dynamic typhoon path modeling and transmission line vulnerability in failure scenarios. Simulating external forces such as typhoons can improve CPS resilience and potentially mitigate large-scale blackouts during disasters.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10991877
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Cascading Failures in Power Cyber-Physical Systems Under Typhoon Conditions

Siqi Wan, Huibin Jia, Bin He, Jiahe Li et al.
Smart Grid Security and Resilience
article

Analysis of Cascading Failures in Power Cyber-Physical Systems Under Typhoon Conditions

Siqi Wan, Huibin Jia, Bin He, Jiahe Li, Chunyan Zhao, Weiran Hou, Longyue Su
article en

Abstract

Given the high coupling of cyber-physical systems in modern power grids, cascading failures are susceptible to natural disasters like typhoons, often leading to widespread blackouts. This study establishes a cascading failure analysis model tailored to typhoon scenarios to assess power CPS vulnerability under extreme weather. First, a typhoon disaster model, based on the Batts model, is constructed to evaluate impacts on transmission lines and initiate failure scenarios. Next, a cascading failure model for power CPS is proposed to simulate failure propagation, followed by simulations analyzing CPS vulnerability under typhoon conditions and assessing physical factors in failure spread. Results underscore the importance of dynamic typhoon path modeling and transmission line vulnerability in failure scenarios. Simulating external forces such as typhoons can improve CPS resilience and potentially mitigate large-scale blackouts during disasters.

North China Electric Power University (CN)
Climate action
Openalex Percentile: Top 63%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.