Research on the Protection Action Strategy for Multi-Terminal AC/DC Converter with Fault Blocking Capability

The multi-terminal AC/DC converter with fault blocking capability is widely used in the power system. In this paper, based on the topology of the multi-terminal AC/DC converter using clamp double sub-module (CDSM), the principle of blocking DC fault current is analyzed under the high-voltage DC bipolar short-circuit fault. The impact of the protection action strategy on the discharge path of the submodule capacitors of AC/DC converter is discussed. Different exit sequences and the locking time of the dual active bridge (DAB) converter and DC/AC inverter are discussed, and the protection action strategy is provided for multi-terminal AC/DC converter. Finally, simulation results are provided for the different protection action strategies.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/ei264398.2024.10991836
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Protection Action Strategy for Multi-Terminal AC/DC Converter with Fault Blocking Capability

Yihan Liu, Huanhuan Qi, Yuhua Ni, Gaocheng Zhang et al.
HVDC Systems and Fault Protection
article

Research on the Protection Action Strategy for Multi-Terminal AC/DC Converter with Fault Blocking Capability

Yihan Liu, Huanhuan Qi, Yuhua Ni, Gaocheng Zhang, Mingqing Chen, Yadong Liu
article en

Abstract

The multi-terminal AC/DC converter with fault blocking capability is widely used in the power system. In this paper, based on the topology of the multi-terminal AC/DC converter using clamp double sub-module (CDSM), the principle of blocking DC fault current is analyzed under the high-voltage DC bipolar short-circuit fault. The impact of the protection action strategy on the discharge path of the submodule capacitors of AC/DC converter is discussed. Different exit sequences and the locking time of the dual active bridge (DAB) converter and DC/AC inverter are discussed, and the protection action strategy is provided for multi-terminal AC/DC converter. Finally, simulation results are provided for the different protection action strategies.

North China Electric Power University (CN), China Electric Power Research Institute, China Agricultural University (CN)
Climate action
Openalex Percentile: Top 72%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.